NIWeek: 8 new USB devices, enhanced digital functions, simultaneous sampling

Multifunction data acquisition platform integrates high-performance analog measurements and control channels, digital I/O and counters and timers in a plug-and-play device.

08/11/2010


National Instruments X Series multifunction data acquisition (DAQ) devices for USBNational Instruments (Nasdaq: NATI) announced NI X Series multifunction data acquisition (DAQ) devices for USB, at NIWeek on Aug. 4. USB X Series devices integrate high-performance analog measurement and control channels, digital I/O and counter/timers onto a plug-and-play device, which engineers and scientists can use for portable test, measurement and data-logging applications. USB X Series DAQ devices include up to 32 analog inputs, four analog outputs, 48 digital I/O lines and four counters. Eight new devices range from 500 kS/s multiplexed AI to 2 MS/s/channel simultaneous sampling AI.

NI LabVIEW graphical programming makes it easy for engineers and scientists to develop custom test and measurement applications for USB X Series using intuitive graphical icons and wires that resemble a flowchart. LabVIEW 2010 simplifies data logging and analysis with a new technical data management streaming option within the NI DAQ Assistant and the ability to export data from a waveform graph to Microsoft Excel or NI DIAdem for post processing. USB X Series devices use the same multithreaded NI-DAQmx driver software as other company DAQ devices, making it easy to port LabVIEW or text-based code from previous applications for use with X Series.

Two technologies that make the devices powerful and easy to use are NI-STC3 technology for advanced timing and triggering and NI Signal Streaming for high-speed, bi-directional data streaming.

At the core of all USB, PCI Express, and PXI Express X Series devices is NI-STC3 timing and synchronization technology, which coordinates the timing and triggering of the analog, digital and counter subsystems. NI-STC3 technology provides X Series devices with independent timing engines for onboard analog and digital I/O subsystems, making it possible for analog and digital I/O to execute independently at different rates or together with synchronization. X Series devices include four enhanced 32-bit counters for frequency, pulse-width modulation (PWM) and encoder operations, as well as a new 100 MHz timebase that can generate analog and digital sampling rates with five times better resolution than previous devices.

USB X Series devices include NI Signal Streaming, a patented technology that uses message-based transfers and device-side intelligence to deliver high-speed, bidirectional data transfer over USB, making it possible to perform analog, digital and counter operations concurrently. With this technology, simultaneous sampling is available on two new devices, which can sample at 1.25 MS/s and 2 MS/s on each of eight analog inputs. These devices are available with 32 or 64 MS onboard memory to guarantee finite acquisitions even with heavy USB traffic. The high sampling rates on all channels make these devices well suited for portable ultrasonic test and transient recording applications.

Each device has a redesigned, extruded aluminum enclosure. The new enclosure offers an easy-access lid to keep signal wiring secure and shielded, and device-specific pinout labels on the lid make it possible to quickly determine the corresponding screw terminals for a given channel. The enclosure also includes a lockable USB port to prevent accidental removal during operation.

See specifications, pricing and demonstration videos for the new USB X Series at www.ni.com/xseries/usb.

See other NIWeek announcements, technologies, and videos.

- Edited by Mark T. Hoske, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me