Multifunctional capacity controller
The AK-PC 781 capacity controller by Danfoss constantly optimizes compressors and condensers and offers oil management, heat reclaim and CO2 control.
The AK-PC 781 Multifunctional Pack Control from Danfoss makes it easy to set up energy-efficient capacity control of refrigeration compressors and condensers with modular hardware and flexible software that extends as system requirements grow or change.
The AK-PC 781 capacity controller ensures precise and stable suction and condensing pressure regulation for a variety of applications and refrigerants. Modules snap onto a common platform to accommodate digital and analog inputs and outputs for compressors, condensers, gas coolers, fans, expansion valves, sensors, switches and alarms. Capacity control is available for up to eight compressors, with three unloaders for each compressor. Functions include speed control of one or two compressors, handling up to six safety inputs per compressor, optional capacity limitation to minimize peak energy consumption, capacity control for up to eight fans and coordinating cascade controllers for medium- and low-temperature operation.
Advanced module features support heat recovery for hot tap water production and general heat recovery in transcritical CO2 booster systems.
Controller programming is easily accomplished with a PC using AK-Service Tool software. The controller networks with other Danfoss ADAP-Kool refrigeration control systems. External data communications is supported by a Modbus extension module.
Each module is 2.8 inches long, with the controller itself consisting of three modules. Aggregate unit length is calculated as number of modules multiplied by module length, plus 0.32 in. Minimum weight is 0.9 lb. The unit is designed for a DIN-rail mount.
Danfoss
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.