M/E Engineering, P.C.: Rochester Regional Health System at Unity Hospital Renovation and Expansion

Retrofit to a hospital/health care facility

08/17/2015


Figure 1: Exterior lighting. Courtesy: M/E Engineering, P.C.Engineering firm: M/E Engineering, P.C.
2015 MEP Giants rank: 50
Project: Rochester Regional Health System at Unity Hospital Renovation and Expansion
Address: Rochester, N.Y., United States
Building type: Hospital/health care facility
Project type: Addition, retrofit, and new construction
Engineering services: Automation, controls; Electrical, power; Fire, life safety; HVAC, mechanical; Lighting; Energy, sustainability; Plumbing, piping
Project timeline: 7/15/2009 to 4/1/2014
MEP/FP budget: $132,000,000

Challenges

The additions and renovations occurred in many locations in a functioning hospital; a high priority was placed on minimizing construction impacts in areas still in use. The design accounted for multiple phases of construction in multiple areas of the hospital over multiple years.

Figure 2: Mechanical/electrical systems. Courtesy: M/E Engineering, P.C.Solutions

M/E Engineering successfully completed the renovation and expansion of Unity Hospital at the Park Ridge Campus, which occurred in many locations and accounted for phases of construction in multiple areas of the hospital over multiple years. The combined renovation and expansion area equates to approximately 320,000 sq ft. Renovation and expansion areas include a new café, a new kitchen, revisions to the main concourse and entrance, four hospital patient wings (including an additional floor of patient rooms), two extended-care patient wings, intermediate care unit (ICMU) patient rooms, cardiology and nuclear medicine, pharmacy, gastroenterology, rehabilitation, sterile support, and dialysis and upgrades to the main utility piping-distribution systems.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me