Industrial drive module includes 230 V ac offering

ABB’s drive module ACS850 provides a compact package that simplifies installation and use, available from 1/2 to 30 horsepower.

03/31/2011


ABB’s ACS850 drive module has bABB ACS850 Familyeen expanded to include a 230 V ac offering, available from ½ to 30 horsepower. The ACS850 features on-board safe-torque-off, a removable memory block, intelligent user interface with a series of assistant wizards, a built-in energy saving calculator, and modular hardware and software. It also includes an advanced adaptation of ABB’s high-performance motor-control platform, Direct Torque Control (DTC).

The ABB industrial drive modules are designed for industrial machinery and applications such as extruders, cranes, mixers, web handling and converting, in the power range 1.5 to 600 hp at 480 V ac and now from ½ to 30 hp at 230 V ac. “The drive is targeted specifically at OEMs, panel builders and system integrators,” said Thomas Junger, product manager for the ACS850. “The 10 hp drive is only 4 inches wide. The sheer quantity of drives that can fit into a cabinet is going to make the ACS850 a popular product.”

Safety as standard is provided by an integrated Safe Torque Off (STO) feature, which removes the torque from the motor shaft. This safety feature conforms with the requirements of SIL 3 / IEC 61508, EN ISO 13849-1:PL e. There also are solutions available for Safe Stop 1(SS1), Safe Limited Speed (SLS), Safe Brake Control (SBC), Safe Speed Monitor (SSM) and Safe Direction (SDI).

A removable memory block increases the flexibility of the drive and allegedly provides for easy maintenance. The memory block stores the complete firmware, plus all user settings and motor data. If the drive is replaced, it can be re-commissioned without any special knowledge via simply plugging the memory block into the new drive. Moreover, the memory block allows the application software and parameter configuration changes to be made at an OEM’s own assembly plant before being sent to the end-user site, just-in-time for commissioning the drive.

The user interface with advanced assistants allegedly decreases the need to refer to manuals, while saving time in commissioning: macros, predefined parameter settings for specific applications, provide for a faster startup - the settings can easily be modified, if required, to customize to your application; the startup assistant guides the user through the needed parameters during the drive startup process allowing for trouble-free and fast commissioning; and other features like short/long parameter menus, I/O mapping, and list of latest parameter changes make the use of the drive easier.

The ACS850 is engineered to work with the latest generation of ABB high-speed serial interface modules. Supported protocols include DeviceNet, Modbus RTU, Profibus, and CANopen. Before the end of 2009, the ACS850 also will support Ethernet/IP and Modbus-TCP. The ACS850 has an automatic energy optimizer that provides for optimum drive efficiency. An on-board energy saving calculator monitors energy usage and indicates the amount of energy saved in kW hours, dollars, and tons of CO2. This tool also illustrates the duration curve, showing the load profile of the drive.

The drive’s internal fan features an automatic on/off control, which provides additional energy savings by switching the cooling fan off when the drive is not active. The same on/off control can control another fan, to cool the cabinet, for example -- saving more energy, and reducing control room noise. The maintenance and diagnostics assistants help keep the process up and running: The maintenance assistant gives an advance warning of maintenance needs of the drive, motor or related components and the diagnostics assistant helps in locating the cause of a disturbance such as overload or over current, and in restoring the process operation.

“The ACS850’s performance at low speed and with permanent magnet motors is truly remarkable, thanks to this advanced adaptation of Direct Torque Control,” said Junger. The performance and functionality of the drive module is based on the ultimate in motor control. Enhanced features include: Improved performance close to zero speed without an encoder, low motor noise mode, higher output frequency (500 Hz) and improved motor identification at standstill.

These compact drive modules, with protection class IP20 (G frame IP00), are optimized for installation into cabinets. The smallest module width is only 3.7 inches. The modules can be installed side-by-side, which saves space as more drives can be placed in the same cabinet, allowing smaller cabinets. The power cable terminals are located optimally for cabinet assembly; with line connection on the top and motor connection on the bottom up to 60 HP. Removable I/O terminals provide for easy cabling and help save time in installation.

The modularity of the product and a wide range of options, such as serial adapters, input/output extensions, and various encoder interfaces, increase the level of drive customization. The large number of standard input/output is allegedly sufficient for most applications but the modular hardware and software design provides OEMs, panel builders and system integrators with the ability to tailor a drive for a specific end-user application by only choosing the options and features required.

The ACS850 uses the most up-to-date PC tool, ABB’s DriveStudio. DriveStudio, 1.5 which features setup wizards that speed up parameter configuration during commissioning and help ensure that all the parameters related to the configuration are addressed, saving time and improving quality.

www.abb.com

ABB

- Edited by Gust Gianos, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me