Gigabit high-power injector for Power over Ethernet

The INJ-24A Gigabit High Power PoE+ Injector from Moxa transmits 60 watts of power to any PD or PoE device and can easily adapt to different power standards with a DIP switch.

05/09/2013


The INJ-24A Gigabit High Power PoE+ Injector transmits 60 watts of power to any PD or PoE device and can easily adapt to different power standards with a DIP switch. Courtesy: MoxaMoxa's INJ-24A Gigabit High-Power PoE+ Injector transmits data and up to 60 watts of power to any PD or Power over Ethernet device, allowing devices on 10/100/1000 networks to safely operate with twice the power of conventional PoE+. (PoE is Power over Ethernet.)

The INJ-24A can quickly adapt to different power standards. By adjusting a DIP switch, the operator can select different power standard modes and even which wire pairs to deliver power on. This allows the INJ-24A to supply power to nearly any PoE device with minimal compatibility obstacles because it can be quickly reconfigured to match the device's settings.

The INJ-24A is designed to transmit data even with potential hazards like power fluctuations, static electricity, and other sources of electromagnetic interference. Media connections are reinforced with protection against power surges of up to 3 kV, while a heat-efficient housing enables the INJ-24A to operate in extremely cold or hot weather (-40 C to 75 C). The built-in 24/48 V dc booster enables the injector to operate on either 24 V dc or 48 V dc.

Smart PoE LED indicators on the INJ-24A also convey the status at a glance so the system operator can immediately identify whether the PoE port is supplying power, and which power supply mode is currently active.

Moxa

www.moxa.com 

See other Control Engineering industrial network products here and linked below.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me