Ethernet box offers analog inputs, outputs on one device

Machine-mountable Beckhoff Automation EP4374 EtherCAT combination I/O box enhances machine design flexibility, with two analog inputs and two analog outputs in one device.

05/28/2011


Beckhoff Automation has reportedly extended its range of IP67 I/O modules with the new EP4374 EtherCAT Box. This flexible, moisture and dust-resistant I/O device combines two analog inputs and two analog outputs into one device. 

The versatile EP4374 I/O box is a reportedly finely scalable EtherCAT solution that empowers machine builders to plan ahead based on demand and, therefore design more cost-effectively. The input and output channels can be parameterized independent of each other for the standard signals 0-10 V, ±10 V, 0-20 mA and 4-20 mA.

With the combination of parameterizable inputs and outputs in a single rugged housing, EP4374 users benefit from increased flexibility and can utilize the existing signals in an optimized manner. This new EtherCAT Box features two input channels and two output channels. Each channel is configurable individually for current or voltage measurement or output. The resolution for the current and voltage signals is 16 bit (signed).

The EP4374-0002 module reportedly has a direct EtherCAT connection, so that the high performance of 100 Mbit/s Industrial Ethernet is retained right down to each IP67 box. The compact dimensions of the EtherCAT Box of only 126 x 30 x 26.5 mm (H x W x D) make it ideal for applications in confined spaces.

For more information:

EP4374 EtherCAT Box

Industrial network news, trends, products, articles: www.controleng.com/networks.

- Edited by Chris Vavra, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.