EC: C440 Electronic Overload Relay

Power - monitoring, protection - Eaton Corporation - C440 Electronic Overload Relay. The C440 provides customers with advanced, reliable and accurate motor protection featuring both integral ground fault protection and communications capabilities, in a single, compact device engineered for machinery original equipment manufacturers (OEMs), project construction and industrial end-user markets. This is a Control Engineering 2011 Engineers' Choice (EC) Honorable Mention.

11/01/2010


C440 Electronic Overload Relay - EatonMotor failure has the potential to cause production downtime, costly repair bills, and numerous safety concerns for plant personnel. For these reasons, motor protection should be a key element in protecting your organization's most valuable assets. Selecting accurate and reliable motor overload protection is the best way to manage your costs and maintain system integrity. The C440 and XT electronic overload relays from Eaton provide reliable, accurate and value driven protection, including communications capabilities, in a single compact device.

The electronic design of Eaton's new C440 Electronic Overload Relay delivers enhanced motor protection based on the ability to directly monitor motor current in each phase. Thermal modeling is performed electronically with precision solid-state components. The electronics accurately identify excessive current or phase loss and react to the condition with greater speed, reliability and repeatability than a traditional electromechanical device.

With a patented, compact design, the new electronic overload relays are easy to install, maintain and configure. Integral communications and ground fault protection means there are fewer devices to install. A light-emitting diode (LED) display on the device provides easy-to-see indication of device status and fault indication, allowing maintenance personnel to quickly determine if the device and motor are operating appropriately.

Customers can select the motor protection features they need, with selectable trip class, ground fault detection, phase imbalance and full load current (FLA) adjustment (5:1). Further, the C440 and XT overload relays can integrate into plant management systems, allowing network monitoring and providing asset protection.

www.eaton.com

www.eaton.com/EatonCom/Markets/Electrical/Products/MotorControl/OverloadRelays/C440Electronic/index.htm

Eaton Corporation          

For more, see www.controleng.com/award.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me