SEARCH Archives
Loading
Sponsored by:

Don't overlook key steps in the safety process

Having a clear plan with executive management and safeguarding yourself against potential hazards for both the short- and long-term is vital

John Peabody, Omron Automation and Safety

11/10/2012


What am I missing in my safety program?

If you think about it too hard, it’s one of those questions that can keep you awake at night. What am I missing in my safety program? Many companies would answer this question by looking at their machines and making sure that all the safeguards are in place. The answer, however, isn’t in the factory—it’s most likely in the corporate offices.

But where does it start? Safety starts at the top and filters down. In a successful program, everyone’s involved. In the most successful companies, safety is a separate item on the agenda for meetings of the board of directors. It’s that important.

First and foremost it’s important to have a clear plan with buy-in from executive management to assess all hazards and a commitment to safeguard (reduce the risk) for each hazard per the plan. This can and should be a long-term plan with milestones and budgets agreed to by the “top brass.” It should have approval for the necessary funding. Without these simple steps, you end up with an environmental health and safety (EH&S) person at the corporate level who is frustrated because he cannot get done what he knows needs to be done.

After management buy-in, from the perspective of the EH&S professional, the following often-overlooked information and processes need to be understood and implemented for a complete and lasting solution: 

  • Risk assessment process—always the beginning of the solution for a safe factory
  • Understanding of the hierarchy of controls (engineered solutions vs. administrative solutions)
  • Understanding of safety circuit design (including practicality, cost, etc.)
  • Identification and application of pertinent regulations (OSHA), standards (ANSI, NFPA, etc.), or directives (machinery directive, plant/corporate standards, etc.)
  • Determination of an internal acceptance of “acceptable (tolerable) risk” (including the difference between being “compliant” and being “safe”)
  • Stakeholder (operations, production, maintenance, etc.) feedback and buy-in for all remediation plans
  • Qualified remediation experts (either in-house or third-party)
  • Understanding of cost vs. value (cheaper usually isn't better)
  • Complete lifecycle review process (Plan, Do, Check, Adjust)
  • Administrative controls (training, documentation, supervision, maintenance, etc.) to maintain safeguarding solutions and practices.  

Whether you tackle these steps with internal resources or hire outside experts to handle your machine safeguarding, if you understand these points—and get executive support and buy-in—you are well on your way to a safer, more efficient factory. 

John Peabody is vice president of business development for Omron Automation and Safety, Fremont, Calif. www.sti.com.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.