Boiler MACT rule now in effect

A Federal appeals court has ruled that the compliance date for the Boiler MACT rule for facilities is March 21, 2012.

02/03/2012


The District of Columbia Circuit Court of Appeals has reinstated the original compliance date for the Boiler MACT (maximum achievable control technology, also known as BMACT or Major Source Rule) that the EPA published in the Federal Register in March 2011. In a ruling on Jan. 9, 2012, District Court Judge Paul Friedman said that a delay of the rules was “arbitrary and capricious” and negated the delay. As a result, owners and operators of certain boilers and process heaters are required to meet work practice standards outlined in the rule by March 21, 2012 and install MACT equipment by March 2014.

Major source facilities are the ones affected by the newly reinstated Boiler MACT. A major source facility is one that emits 10 or more tons per year of any single air toxic or 25 tons or more per year of any combination of air toxics. A comprehensive list of the regulated air toxics can be found on the EPA website. Very large industrial facilities, such as refineries, chemical and large manufacturing plants, and large institutional facilities such as universities typically are classifed as major source facilities.

If a facility is not a major source, it is classified as an area source and is required to meet a different set of regulations that are in effect. For more information about the Area Source Rule, visit www.cleaverbrooks.com/epa.

Requirements for both major source and area source facilities vary depending upon: the type of fuel combusted, boiler commissioning date, and boiler size. For the Major Source Rule, EPA has identified 15 different subcategories of boilers and process heaters based on the design of the various types of units. The final rule includes specific requirements for each subcategory. Necessary actions range from conducting regular tune-ups to meeting numeric emissions limits. Facilities also must maintain records and file periodic reports to demonstrate compliance.

Below is a summary of the requirements of the Boiler MACT for major source facilities. For the complete rule that is published in the Federal Register, visit http://www.gpo.gov/fdsys/pkg/FR-2011-03-21/pdf/2011-4494.pdf 

- For all new and existing gas- and refinery gas-fired units, the operator must perform an annual tune-up for each unit. Units combusting other gases can qualify for work practice standards by demonstrating that they burn “clean fuel,” with contaminant levels similar to natural gas.

- For all new and existing units with a heat input capacity less than 10 MMBtu/hr, the operator is required to perform a tune-up for each unit once every two years.

- For all new and existing “limited use” boilers (defined as those operated less than 10 percent of the year as emergency and back-up boilers to supplement process power needs), the operator is required to perform a tune-up for each unit once every two years.

- The final rule establishes numeric emission limits for all other existing and new boilers and process heaters located at major sources. The final rule establishes emissions limits for:

  • Mercury
  • Dioxin
  • Particulate matter (PM) as a surrogate for non-mercury metals
  • Hydrogen chloride (HCI) as a surrogate for acid gases 
  • Carbon monoxide (C) as a surrogate for non-dioxin organic air toxics.

- The largest major source boilers are required to continuously monitor their particle emissions. All units larger than 10 MMBtu/hr must monitor oxygen as a measure of good combustion.

- Existing major source facilities are required to conduct a one-time energy assessment to identify cost-effective energy conservation measures.

While the Area Source Rule has been in effect since being published in March 2011, the Major Source Rule has not. In May 2011, EPA issued a notice of delay and asked for a stay of the rules to give the agency more time to evaluate feedback from the industry.

In July 2011, the Sierra Club petitioned the appellate court for review of the EPA’s delay notice, contending that the original rules will help reduce illnesses such as lung cancer and asthma. EPA issued a revised proposal in December 2011 that agency officials said is less costly for affected boiler owners than the original proposal, but still meets the necessary requirements laid out in the 1990 Clean Air Act amendments. However, Judge Friedman’s ruling reinstates compliance deadlines set in the earlier March 2011 rule.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.