Belden: Hirschmann Mach 1040 Gigabit Ethernet Switch for high network availability, safety

Belden: new Hirschmann Mach1040 Gigabit Ethernet Switch delivers high network availability and operational safety.

03/06/2010


Belden (NYSE: BDC) introduces the new Hirschmann Mach 1040 Gigabit Ethernet Switch for high network availability and operational safety. The Mach 1040 Gigabit Ethernet Switch is a 19-in. rack-mount Layer-2 switch with either 16 front or rear-facing Gigabit Ethernet RJ45/SFP combo ports (the Small-Form factor Pluggable ports support 100 mbps and Gigabit transceivers).

The rear-facing option provides a cleaner look and restricts unauthorized access to the cabling and all ports support version 2 of Precision Time Protocol (IEEE 1588 version 2) while 4 of the 16 ports are available with Power over Ethernet (IEEE 802.3af). Software is currently under development to enable this switch to be used as a router.

The RJ45/SFP combo ports facilitate the flexible implementation of high-speed data networks without additional investment or costs for future retrofits or extensions, Belden says. Designed for assembly in 19-in. cabinets, the Mach 1040 uses the latest energy-saving chip technology, providing an extremely low thermal footprint despite being fan-less. Its rugged metal housing measures 448 by 44 by 310 mm (width, height and depth). Boot time is only 10 seconds. By connecting an ACA 21-USB auto-configuration adapter to its USB port, all configuration data and operating system can be saved and recalled at any time without tools or a PC - even onto a replacement switch.

Dual fault alarm contacts are available for detecting the status of the switch and detailed information can be displayed by means of a standard web browser. Additional management functions include Command Line Interface, Management Information Base, Telnet, HTTP, TFTP as well as SFP Management. In addition, an SNMP interface permits the use of network management software, such as HiVision and HiDiscovery.
Media redundancy capabilities, such as Fast Hiper Ring, MRP (IEC ring function), Trunking, Link Aggregation and Rapid Spanning Tree, provide for high network availability. Security mechanisms include access control according to IEEE 802.1x, IP and MAC port security as well as SNMP V3 und SSH.

Additional characteristics include an operating temperature range of -40 °C to +70 °C, high resistance to shock, vibration electrical discharge and magnetic fields. Passive, fan-less cooling and optional redundant power supplies are added to ensure high operational safety. The Mach 1040 Gigabit Ethernet switch meets the standards and approval requirements of IEC 61850, IEEE 1613, EN 50121-4, EN 50155, cUL 508, cUL 1604 C1 Div2 and GL making it ideal for use in power generation and electrical power distribution application.

Belden delivers copper and fiber cabling/connectivity systems, wireless technologies, and active switch devices. www.hirschmann-usa.com

- Edited by Mark T. Hoske, editor in chief, Control Engineering, www.controleng.com.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.