Basics of power transmission chain

A chain is a reliable machine component that transmits power by tensile force. Chains may be classified in many ways. From one viewpoint, chain is a continuous, flexible rack engaging a pair of gears. Another viewpoint terms chain a mechanical belt, running over wheels, which can be used to transmit power.

07/01/2005



A chain is a reliable machine component that transmits power by tensile force. Chains may be classified in many ways. From one viewpoint, chain is a continuous, flexible rack engaging a pair of gears. Another viewpoint terms chain a mechanical belt, running over wheels, which can be used to transmit power. Chain is basically a set of pins, rollers, bushings, and connecting links (Fig. 1).

Power transmission chain competes with V-belts, synchronous belts, and gear drives. Each has properties that enable them to carve out a niche all their own. However, there are applications where it can be an either/or situation.

Features of chain drives:

Advantages

  • Speed reduction/increase of up to 7:1 can be easily accommodated.

  • Can handle long shaft center distances.

  • It is possible to use chain with multiple shafts or drives and both sides of the chain.

  • Standardization of chains allows ease of selection.

  • It is easy to cut and connect chains.

  • Chain sprockets can be smaller than belt pulleys and transmit the same torque.

  • Sprockets wear less than gears because the load is distributed over many teeth.

  • Chain is more suitable for long-term, continuous power transmission with limited torque fluctuation.

    • Disadvantages

      • Chain has speed variations.

      • Chain needs lubrication.

      • Chain wears and elongates.

      • Chain is weak when subjected to side loads.

        • Chain selection

          When making drive selections, consider the load imposed on the chain by the input power and type of equipment to be driven, Service factors are used to determine design horsepower or additional chain capacity required to compensate for the load (Fig. 2).

          Lubrication

          Lubrication is an important factor in obtaining the desired life from a chain. In drives where the chain is operated at established ratings, proper lubrication is as much a part of the rating as the load and speed promised by the rating.

          Power transmission chains are usually pre-lubricated with rust prevention oil before shipping. However, it is essential to lubricate roller chain. Properly lubricated chain has a longer wear life and is less likely to rust.

          Obtaining effective lubrication for a chain is a matter of correct application in terms of lubricant used and how and where in the strand it is provided. Lubricate the chain where tension is minimal, applying the lubricant in the clearance between link plates.

          In manual lubrication, oil is applied with an oil can or brush. Apply oil about every eight hours or as needed.

          In drip lubrication, oil is metered from an oil cup at 5 to 20 drops of oil per minute. The actual quantity depends on chain speed.

          Oil bath lubrication submerges part of a sprocket and chain in a pool of oil. Do not have the chain submerged more than

          Drive chain arrangements

          The relative position of the driver and driven sprockets and the tight- and slack side strands greatly influence the drive life (Fig. 3).

          Plant Engineering magazine extends its appreciation to U.S. Tsubaki, Inc. for their assistance in the preparation of this article. They supplied the illustration for Fig. 1 and the flow chart for Fig. 2.

          Power transmission comparison

          <table ID = 'id2765676-95-table' CELLSPACING = '1' CELLPADDING = '3' BORDER = '0'><tr ID = 'id2765686-95-tr' STYLE = 'background-color: #CCCCCC'><td ID = 'id2765690-95-td' CLASS = 'copy'> Property </td><td ID = 'id2765697-97-td' CLASS = 'copy'> Roller chain </td><td ID = 'id2765704-99-td' CLASS = 'copy'> V-belt </td><td ID = 'id2765711-101-td' CLASS = 'copy'> Toothed belt </td><td ID = 'id2765718-103-td' CLASS = 'copy'> Gear train </td></tr><tr ID = 'id2743710-178-tr'><td ID = 'id2743712-178-td' CLASS = 'tfoot' COLSPAN = '5'>E = Excellent G = Good F = Fair P = Poor
          (Courtesy of U.S. Tsubaki, Inc.)
          </td></tr><tbody ID = 'id2765726-107-tbody'><tr ID = 'id2765729-107-tr' VALIGN = 'middle' STYLE = 'background-color: #EEEEEE'><td ID = 'id2765735-107-td' CLASS = 'table'> Synchronization </td><td ID = 'id2765742-109-td' CLASS = 'table'>E</td><td ID = 'id2765748-110-td' CLASS = 'table'>P</td><td ID = 'id2765753-111-td' CLASS = 'table'>E</td><td ID = 'id2765759-112-td' CLASS = 'table'>E</td></tr><tr ID = 'id2743378-114-tr' VALIGN = 'middle' STYLE = 'background-color: #EEEEEE'><td ID = 'id2743384-114-td' CLASS = 'table'> Transmission efficiency </td><td ID = 'id2743391-116-td' CLASS = 'table'>E</td><td ID = 'id2743396-117-td' CLASS = 'table'>F</td><td ID = 'id2743402-118-td' CLASS = 'table'>E</td><td ID = 'id2743408-119-td' CLASS = 'table'>E</td></tr><tr ID = 'id2743414-121-tr' VALIGN = 'middle' STYLE = 'background-color: #EEEEEE'><td ID = 'id2743421-121-td' CLASS = 'table'> Anti-shock </td><td ID = 'id2743427-123-td' CLASS = 'table'>F</td><td ID = 'id2743433-124-td' CLASS = 'table'>E</td><td ID = 'id2743438-125-td' CLASS = 'table'>G</td><td ID = 'id2743444-126-td' CLASS = 'table'>P</td></tr><tr ID = 'id2743451-128-tr' VALIGN = 'middle' STYLE = 'background-color: #EEEEEE'><td ID = 'id2743457-128-td' CLASS = 'table'> Noise/vibration </td><td ID = 'id2743464-130-td' CLASS = 'table'>F</td><td ID = 'id2743469-131-td' CLASS = 'table'>E</td><td ID = 'id2743475-132-td' CLASS = 'table'>G</td><td ID = 'id2743480-133-td' CLASS = 'table'>P</td></tr><tr ID = 'id2743487-135-tr' VALIGN = 'middle' STYLE = 'background-color: #EEEEEE'><td ID = 'id2743493-135-td' CLASS = 'table'> Surrounding condition </td><td ID = 'id2743500-137-td' CLASS = 'table'>Avoid water, and dust</td><td ID = 'id2743506-138-td' CLASS = 'table'>Avoid heat, oil, water, and dust</td><td ID = 'id2743511-139-td' CLASS = 'table'>Avoid heat, oil, water, and dust</td><td ID = 'id2743517-140-td' CLASS = 'table'>Avoid water and dust</td></tr><tr ID = 'id2743523-142-tr' VALIGN = 'middle' STYLE = 'background-color: #EEEEEE'><td ID = 'id2743530-142-td' CLASS = 'table'> Space saving : High speed, low load</td><td ID = 'id2743538-144-td' CLASS = 'table'>P</td><td ID = 'id2743543-145-td' CLASS = 'table'>G</td><td ID = 'id2743549-146-td' CLASS = 'table'>E</td><td ID = 'id2743554-147-td' CLASS = 'table'>G</td></tr><tr ID = 'id2743561-149-tr' VALIGN = 'middle' STYLE = 'background-color: #EEEEEE'><td ID = 'id2743567-149-td' CLASS = 'table'> Space saving : Low speed, high load</td><td ID = 'id2743575-151-td' CLASS = 'table'>E</td><td ID = 'id2743581-152-td' CLASS = 'table'>P</td><td ID = 'id2743586-153-td' CLASS = 'table'>F</td><td ID = 'id2743592-154-td' CLASS = 'table'>G</td></tr><tr ID = 'id2743598-156-tr' VALIGN = 'middle' STYLE = 'background-color: #EEEEEE'><td ID = 'id2743605-156-td' CLASS = 'table'> Lubrication </td><td ID = 'id2743612-158-td' CLASS = 'table'>P</td><td ID = 'id2743617-159-td' CLASS = 'table'>E</td><td ID = 'id2743622-160-td' CLASS = 'table'>E</td><td ID = 'id2743628-161-td' CLASS = 'table'>P</td></tr><tr ID = 'id2743634-163-tr' VALIGN = 'middle' STYLE = 'background-color: #EEEEEE'><td ID = 'id2743641-163-td' CLASS = 'table'> Layout flexibility </td><td ID = 'id2743648-165-td' CLASS = 'table'>E</td><td ID = 'id2743653-166-td' CLASS = 'table'>F</td><td ID = 'id2743659-167-td' CLASS = 'table'>G</td><td ID = 'id2743664-168-td' CLASS = 'table'>P</td></tr><tr ID = 'id2743671-170-tr' VALIGN = 'middle' STYLE = 'background-color: #EEEEEE'><td ID = 'id2743677-170-td' CLASS = 'table'> Excess load on bearings </td><td ID = 'id2743684-172-td' CLASS = 'table'>E</td><td ID = 'id2743689-173-td' CLASS = 'table'>P</td><td ID = 'id2743695-174-td' CLASS = 'table'>F</td><td ID = 'id2743700-175-td' CLASS = 'table'>E</td></tr></tbody></table>



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me