Automated gripper set for handling and assembly systems

Parallel, three-point, radial and angle DHxS grippers from Festo are designed for handling and assembly systems and have gripping force retention and overload protection for safety.

03/23/2012


The parallel, three-point, radial and angle gripper series DHxS from Festo offers increased reliability in a range of sizes and stroke lengths. Courtesy: FestoThe parallel, three-point, radial and angle standard grippers, DHxS, from Festo are compact and offer reliability in the gripping process. Standard grippers are the first choice for cost-effective, lightweight and compact construction of handling and assembly systems. The parallel, three-point, radial and angle gripper series DHxS from Festo features optimized gripping force retention and overload protection as well as integrated sensor slots. It offers increased reliability in a range of sizes and stroke lengths.

A number of features ensure reliability and precision. The integrated fixed restrictor provides an effective safety buffer, protecting against overloading during high-speed gripper motions and preventing damage due to excessive forces. The integrated sensor slots in the medium and large sizes offer the advantage of cost-effective stroke sensing via sensors SMx. Their successful integration has resulted in a slim, compact design without any interference contours caused by external sensors. The new, compression spring-assisted gripping force retention provides more security in the event of a pressure failure. In addition, T-slot guides increase the torque resistance of the gripper jaws.

The double-acting piston drive gives the standard grippers stable kinematics and maximum repetition accuracy. A wide range of mounting options in the form of threaded, fitting and centering holes make the new generation of Festo standard grippers very flexible to mount. 

The parallel and three-point grippers DHxS have a lightweight aluminum housing with integrated receiving hole for the pneumatic piston. The force generated by the linear motion is transferred to the low-backlash gripper jaws by means of lever kinematics. Since the lever is indirectly in mesh with the two gripper jaws via a piston rod, there is no need for additional synchronization.

The pneumatic pistons of the double-acting DHxS radial and angle grippers act on the gripper jaws, mounted on pivots in a gripper jaw guide, by means of a slotted guide system. As with parallel and three-point grippers, this means that there is no need for separate synchronization.

Festo

www.festo.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

See more on motors, drives, and motion control from Control Engineering at http://www.controleng.com/new-products/motors-and-drives.html 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me