Analysis software allows tuning in the frequency domain

Frequency Analysis Software from Galil Motion Control allows tuning of servo control systems in the frequency domain, often preferred for systems with resonances or when the design engineer is comfortable with classroom control theory.

07/29/2011


Galil Motion Control Frequency Analysis Software (FAS) allows tuning of servo control systems in the frequency domain. Tuning in the frequency domain is often preferred for systems with resonances or when the design engineer is comfortable with classroom control theory.

“While in most cases tuning servo systems in the time domain works well (Galil’s GalilTools software provides tuning in the time domain), Galil’s new Frequency Analysis Software provides an alternative option for tuning systems,” said Lisa Wade, vice president of sales and marketing. “It is especially useful for tuning systems with resonances.”

The new software in conjunction with a Galil motion controller measures the frequency response of the plant to be controlled. It simulates the possible control solutions and synthesizes the two to allow for Bode analysis of the closed loop system.

FAS plots the magnitude versus frequency and phase versus frequency for both the Galil motion controller and the plant. The plant’s frequency response is measured from the actual plant. The controller’s response is simulated based on the selected control parameters. The product of the two functions is the system open loop frequency response.

FAS allows the designer to try various simulations of the controller parameters such as the PID filter and notch parameters and combine them with the plant to give the open loop frequency response. Based on the simulations, the designer can determine the best controller parameters to meet the desired performance criteria of phase margin and cross-over frequency for his system.

Galil Motion Control Inc.

www.galilmc.com

- Edited by Amanda McLeman, Control Engineering, www.controleng.com

See more about motors, drives, and motion control:

http://www.controleng.com/new-products/motors-and-drives.html



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me