Adapter creates tool-free interface to IO modules

Wago Corporation's Interface Adapter provides a tool-free interface and captures analog/digital signals for eight combined modules - ideal for machines requiring large amounts of input/output signals.

05/11/2011


Wago Corporation’s new Interface Adapter provides Jumpflex Signal Conditioners and Relays with a tool-free interface to the Wage-I/O-System or other PLC interfaces. Interface Adapters capture analog/digital signals for eight combined Jumpflex modules — ideal for machines requiring large amounts of input/output signals. Ribbon cable and D-Sub connector models provide 8-channel connectivity; other interface products connect the Interface Adapters to Wago’s 16-Channel Digital I/O modules.

Jumpflex Interface Adapters streamline commissioning and eliminate wiring errors for both field and control levels. To simplify troubleshooting, each Interface Adapter features marking tag holders and a test location at each channel. Integrated indicators for signal and/or power status are also included. Complementary products include DIN-rail mount interface boards and relay modules.

Jumpflex Signal Conditioners and Relays feature an ultra-compact 6mm, DIN-rail mount housing and a flexible jumpering system that reportedly eliminates redundant wiring. All models provide safe isolation of input, output and supply circuits with 2.5 kV test voltage to EN 61140. Signal transmission is attained with an accuracy <0.1% of the full scale value, according to Wago. The Signal Conditioner modules are rated -25 to +70°C for wide variety of industrial sensors.

www.wago.us

Wago Corporation

- Edited by Amanda McLeman, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me