4-axis 750 W servo drive for Ethernet motion controllers

Galil adds to multi-axis drive family, the packaging of multio-axis drives with motion controllers saves cost, space, wiring.

SOURCE: Galil Motion Control Inc.

03/15/2011


Galil Motion ControGalil DMC Familyl added the AMP-43240 to its multi-axis drive family. The AMP-43240 is a 4-axis servo drive which provides up to 750W per axis. It resides inside Galil’s DMC-4040 or DMC-4143 4-axis motion controller enclosure. The packaging of the multi-axis drives with the motion controller reportedly saves cost, space and wiring.

The new Amp-43240 contains four transconductance, PWM amplifiers for driving brushless servo motors at 20-80 V dc. Each amplifier drives motors operating up to 10 A continuous, 20 A peak per axis. The gain settings of the amplifier are user-programmable at 0.5, 1.0 and 2.0 Amp/Volt. The switching frequency is 24 kHz. The amplifier offers protection for over-voltage, under-voltage, over-current, short-circuit and over-temperature. A shunt regulator option is available.

The packaging of the 4-axis drive inside the motion controller enclosure saves space compared to using external drives. The DMC-4040 4-axis controller and drive package dimensions are 8.1 x 7.3 x 1.7-inch. Two 4-axis drives can also be installed inside the DMC-4080 8-axis controller package which measures 11.5 x 7.3 x 1.7-in. Other multi-axis drives available from Galil include 20 W and 500 W servo drives and drives for stepper motors.

Detailed specifications for Galil’s DMC-41x3 and DMC-40x0 motion controllers and drives.

www.galilmc.com

Galil Motion Control Inc.

- Edited by Gust Gianos, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.