Codes & Standards: Engineers Wanted

Codes and standards stand to benefit from the expertise of engineers

By BARBARA HORWITZ, Associate Editor -- Consulting-Specifying Engineer, 5/1/2001

Who better understands the way buildings live, operate and breathe than the engineers who design them? So when it comes to ensuring safety in facilities via codes and standards, wouldn't it make sense for engineers to be intimately involved in the development process?

Ideally, yes. But practically, it's not so simple.

"We feel strongly about participating [in the codes- and standards-making process], but unless we are sponsored, we cannot participate actively because we can't really afford the time and money to send someone to two to three meetings a year for four to five years," explains Steven Winter, an architect and president of Steven Winter Assoc., Inc., an M/E, building-research and sustainable design firm based in Norwalk, Conn.

Lawrence G. Spielvogel, P.E., an independent consultant based in King of Prussia, Pa., is very involved in the process, particularly through the American Society of Heating, Refrigerating and Air-Conditioning Engineers, but concurs that it's somewhat challenging to make the time.

"I wish it could be easier for everybody to get involved but it can be contentious, time-consuming and expensive to participate," says Spielvogel.

Engineers welcome

Unlike engineers, manufacturers often have the wherewithal—and the motivation—to allocate staff and resources to the cause, especially because designing their equipment to meet codes and standards is such a big item in their budgets, according to John Kampmeyer, P.E., an engineer with Triad Fire Protection Engineering in Springfield, Pa. But unlike manufacturers, consulting engineers often offer a more objective view of building performance.

"Product manufacturers and scientists may have a lot to add, but it's the architects and engineers who have a global view of how these technologies fit into buildings," says Winter.

Casey Grant, P.E., assistant chief engineer for the National Fire Protection Association, Quincy, Mass., agrees with the notion. "Engineers bridge the gap by implementing technology and bringing that into practical world reality."

Grant also notes that there are a number of benefits that engineers gain through participation, such as influencing codes and standards, networking with colleagues who are dealing with the same challenges and receiving industry recognition for their efforts.

Spielvogel echoes those advantages, adding that codes and standards involvement can be very fulfilling work as well as an opportunity to market one's firm or oneself.

Keeping up

Another major benefit of participation is the ability to stay current on pertinent information that engineers are ultimately responsible for knowing.

"If you're not involved, it's very difficult to understand the impact of the codes," says Kampmeyer. "It's not just throwing a fire damper on a duct; you have to understand why it needs to be there."

Spielvogel and Winter concur that it is very difficult for engineers to keep up with what codes and versions are in effect in different jurisdictions at any given time.

"Engineers have a tough time," notes Winter. "They either have to study the code like mad or hire a code consultant."

Not only do experienced engineers find it challenging, but new graduates are significantly less prepared to deal with codes, according to code consultant Kelly P. Reynolds of Kelly Reynolds & Assoc., Chicago.

However, due to the consolidation of national building codes and trends toward greater uniformity among jurisdictions, Reynolds predicts that engineering curricula will eventually change to reflect this.

"I expect to see codes questions on licensure exams in the next three to six years," claims Reynolds. "That means that colleges are going to have to start teaching codes."

State Building Codes: A Handy Reference
State Plumbing Code Mechanical Code Electrical Code Fire/Life-Safety Code Energy Code
AL SPC 1994 (Ala. State Building Code), no amendments1 SMC 1994 (Ala. State Building Code), no amendments1 NEC 1996 (Ala. State Building Code), no amendments1 SFPC 1994; NFPA 101, 1997; NFPA 1, 1997; NFPA 1998 (Regulations of the State Fire Marshal), no amendments2 ASHRAE 90.1 (Ala. Building Energy Conservation Code)3
AK UPC 2000, no amendments IMC 2000, no amendments4 NEC 1999, no amendments IFC 20004 Alaska Building Energy Efficiency Standards5
AZ None None None UFC 1997 ASHRAE 90.1, no amendments6
AR7 Ark. State Plumbing Code 1995 SMC 1997, no amendments NEC 1999, no amendments SFPC 1997 ASHRAE 90.1-1989 no amendments
CA8 UPC 1997 (Calif. Plumbing Code 1998) UMC 1997 (Calif. Mechanical Code 1998) NEC 1996 (Calif. Electrical Code 1998) UFC 1997 (Calif. Fire Code 1998) Calif. Energy Code 1998 (Title 24, Part 6)
CO9 UPC 1997, no amendments UMC 1997, no amendments NEC 1996, no amendments None MEC 1993, no amendments
CT8 IPC 1997 (State Building Code, 2000 Conn. supplement) IMC 1996 (State Building Code, 2000 Conn. supplement) NEC 1999 (State Building Code, 2000 Conn. supplement) NFPA 101, 1997 (State Fire Code, 2000 Conn. supplement) 95 MEC; ASHRAE/IES 90.1 (2000 Conn. supplement)
DE7 None None NEC 1999, (State Fire Prevention Regulations), no amendments State Fire Prevention Regulations; NFPA 101, 1997 MEC 1993: ASHRAE 90.1-1989 (Del. Code, Title 16, Part 7, Ch. 76)
FL7 SPC 1994, no amendments SMC 1997, no amendments NEC 1996, no amendments SFPC 1991, no amendments Fla. Energy Efficiency Code for Bldg. Constr.
GA IPC 2000 (Ga. State Minimum Standard Plumbing Code) IMC 2000 (Ga. State Minimum Standard Mechanical Code) NEC 1999, (Ga. State Minimum Standard Electrical Code) SFPC 1994 (Ga. State Minimum Standard Fire Prevention Code MEC 1995: ASHRAE 90.1 (Ga. State Energy Code for Buildings)
HI None Administrative Rules, Title 11, Ch. 39, Air Conditioning Ventilating None 1998 UFC with 1989 and 1990 supplements (State Model Fire Code)10 ASHRAE 90.1 (Hawaii Model Energy Code)4
ID7 UPC 1997 (Administrative Laws, Title 2, Ch. 6) None NEC 1999, no amendments UFC 1997 No commercial code
IL Ill. Plumbing Code7 None None NFPA 101, 1991 edition with all standards referenced in Chapter 3212 N/A
IN8 UPC 1997 (Ind. Plumbing Code, 1999 edition) IMC 1996 (Ind. Mechanical Code, 1997 edition) NEC 1999 UFC 1997 (Ind. Fire Code, 1998 Edition) MEC 1992 (Ind. Energy Conservation Code)
IA UPC 1994 [Iowa State Building Code 1994 (ISBC)]6 UMC 1994 [Iowa State Building Code 1994 (ISBC)]6 NEC 1996 [Iowa State Building Code 1994 (ISBC)]6 NFPA (State Fire Marshal Rules)6 MEC 1992; ASHRAE 90.1-1989 (Iowa State Building Code)
KS UPC 1997, no amendments6 UPC 1997, no amendments6 NEC 1999, no amendments6 NFPA 1997; NFPA 101 1997 (Kan. Fire Prevention Code) 7 ASHRAE 90.1-1989 (Kan. Corp. Commission Order), no amendments11
KY8 Ky. Plumbing Code 2000 NMC 1993 (1997 Ky. Building Code) NEC 1999 (1997 Ky. Building Code) NFPA 1, 1997: NFPA 101, 1997 (1999 Ky. Fire Prevention Code) ASHRAE 90A-1980 & 90B-1975; MEC 1992
LA SPC 1991 with 1992 La. Amendments7 None NEC 1996, no amendments12 NFPA 101, 1997, no amendments12 ASHRAE 90.1, no amendments13
ME Maine State Plumbing Code (Code of Maine Rules 10, Chapter 238) None NEC 1999 NFPA 101, 1997 N/A
MD NSPC 1993 with 1994 supplement and Ch. 3 of 1995 supplement7 IMC 1996 (Model Performance Code), no amendments6 NEC 1996 (State Fire Prevention Code), no amendments7 NFPA 1, 1997; NFPA 101, 1997 (State Fire Prevention Code)7 MEC 1995; NECC 1996 (Building Energy Standards)
MA8 Mass. State Plumbing Code, CMR 248 Mass. State Plumbing Code, CMR 248 NEC 1999 (Mass. Elec. Code. CMR 527) Mass. Fire Prevention Regulations, CMR 527 ASHRAE 90.1 [Mass. State Building Code, Article 13 (780 CMR)]
MI8 IPC 1997 (Plumbing Code Rules, Part 7 IMC 1996 (Mechanical Code Rules, Part 9a) NEC 1996 (Electrical Code Rules, Part 8) NFPA 101, 198514 Michigan Energy Code
MN8 Minn. Dept. of Health Plumbing Code, Chapter 4715 UMC 1991 with 1994 amendments (Minn. Mechanical Code, Minn. Rules, Chapter 1346) NEC 1999 (Minn. State Building Code, Minn. Rules, Chapter 1315) UFC 1997 (Minn. Rules, Chapter 7510) Minn. Energy Code (Minn. Rules, Chapter 7670-7678)
MS SPC 1988, no amendments SMC 1988, no amendments N/A SFPC 1997 (Miss. Fire Prevention Code)15 None
MO8 IPC 1995, no amendments IMC 1996, no amendments NEC 1999, no amendments NFPA 1, 1997: NFPA 101, 1997, no amendments ASHRAE 90.1-1989, no amendments
MT UPC 1997 (Administrative, Rules of Mont., Ch. 70, Bldg. Codes Bureau)8 UMC 1997 (Administrative, Rules of Mont., Ch. 70, Bldg. Codes Bureau)8 NEC 1999 (Administrative Rules of Mont., Ch. 70, Bldg. Codes Bureau)11 UFC 1994 (Administrative Rules of Mont. Ch. 7)8 MEC 1993; ASHRAE 90.1 (Administrative Rules of Mont., Chapter 70)11
NE None None NEC 19997 NFPA; NFPA 101, 1994 (Neb. State Fire Code Regulations, Title 153)7 MEC 198316, IECC 19986
NV7 UPC 1994 (Nev. Revised Statutes, Title 40, Ch. 444) UMC 1991 NEC 1993, no amendments UFC 1991; NFPA 101, 1994 MEC 1986
NH NPC 1993 (State Plumbing Code)7 None NEC 1999 (Electricians Board Rules & State Fire Code)7 NFPA 1, 1997; NFPA 101, 1997 (State Fire Code)7 ASHRAE 90.1-198918
NJ6 NSPC 1996 (N.J. Uniform Construction Code)7 NMC 1993 (N.J. Uniform Construction Code) NEC 1999 (N.J. Uniform Construction Code) NFPC 1996 (N.J. Uniform Construction Code, Sub-chapter 3) NECC 93 (N.J. Uniform
NM UPC 1997 (1997 N.M. Plumbing & Mechanical Code)7 UMC 1997 (1997 N.M. Plumbing & Mechanical Code)7 NEC 1999 (1999 N.M. Electrical Code)7 NFPA 1, 1997: NFPA 101, 1997, no amendments7 MEC 1986, no amendments19
NY7 N.Y. State Uniform Fire Prevention and Building Code, Title 9B N.Y. State Uniform Fire Prevention and Building Code, Title 9B N.Y. State Uniform Fire Prevention and Building Code, Title 9B N.Y. State Uniform Fire Prevention and Building Code, Title 9B N.Y. State Energy Conservation Constr. Code, Title 9G
NC12 SPC (N.C. State Building Code, Vol. II) SMC (N.C. State Building Code, Vol. III) NEC (N.C. State Building Code, Vol. IV) SFPC (N.C. State Building, Code, Vol. V) ASHRAE 90.1 (N.C. State Building Code, Vol. X)
ND8 UPC 199611 UMC 1997 (N.D. Century Code, State Building Code, Chapter 54-21.3 NEC 1999 (N.D. Wiring Standards)11 UFC 1997: NFPA 101, 199711 MEC 1993, no amendments
OH12 IPC 1995 (Ohio - Plumbing Code 1998 with 1999 amendments) IMC 1996 (Ohio Basic Mechanical Code 1998 with 1999 amendments) NEC 1999 (Ohio Basic Building Code 1998 with 1999 amendments) NFPC 1996 (Ohio Fire Code 1998) MEC 1995: ASHRAE 90.1 (Ohio Basic Building Code 1998, Chapter 13)
OK12 None None None NFPC 1996: NFPA 101, 1997 ASHRAE 90.16
OR UPC 1997 (Ore. Plumbing Specialty Code, 2000) IMC 1998 (1999 Ore. Mechanical Specialty Code) NEC 1999 (Ore. Electrical Specialty Code) UFC 1997 (Ore. Fire Code) Ore. Structural Specialty Code, Chapter 13
PA None None None Fire and Panic Regulations (Penn. Code, Title 34, Chapters 49-59) ASHRAE 90A-1980; ASHRAE 908-1975 (Bldg. Energy Conservation Act), no amendments
RI8 IPC 1995 (R.I State Building Code) IMC 1996 (R.I. State Building Code) NEC 1996 (R.I. State Building Code) NFPA 101, 1997; NFPA 1, 1997 (R.I. Fire Safety Code) ASHRAE 90.1 (R.I. State Building Code)
SC8 SPC 1997, no amendments SMC 1997, no amendments NEC 1999, no amendments SFPC 1997, no amendments MEC 1995
SD NSPC 1996 (Plumbing Commission Rules)7 UMC 1994 (Fire Safety Standards)19 NEC 1999, (Wiring Bulletin of S.D.)7 UFC 1994 (Fire Safety Standards)19 None
TN12 SPC 1997, no amendments SMC 1997, no amendments NEC 1996 (Rules of the Tenn. Dept. of Commerce & Ins., Ch. 0780-2-1) NFPA 1, 1997; NFPA 101,1997, no amendments MEC 1992, no amendments21
TX None None None NFPA 101, 199421 ASHRAE 90.1; MEC 199311
UT8 IPC 1997 (Utah Uniform Bldg. Standard Act Rules, Rule R156-56) IMC 1998 (Utah Uniform Bldg. Standard Act Rules, Rule R156-56) NEC 1996 (Utah Uniform Bldg. Standard Act Rules, Rule R156-56) UFC 1997 (Utah Rules Pursuant to the Utah Fire Prevention Law, Rule R710-9) 16MEC 1995; ASHRAE 90.1-1989
VT NPC 1990, (State of Vt. Plumbing Rules)23 NMC 1987 with 1988 supplement (1994 Vt.- Fire Prevention & Building Code)7 NEC 1999 (1999 Vt. Electrical Safety Rules) NFPA 1, 1997; NFPA 101,1997 (1999 Vermont Fire Prevention & Building Code)7 ASHRAE 90.1-1980 (1994 Vermont Fire Prevention & Building Code)6
VA8 IPC 1995 with 96 supp. (Va. Uniform Statewide Building Code) IMC 1996 (Va. Uniform Statewide Building Code) NEC 1996 (Va. Statewide Building Code) NFPC 1996 (Va. Statewide Fire Prevention Code), no amendments NECC 1996, no amendments
WA UPC 1997 (State Bldg. WAC Chapter 51-46 and 51-47) UMC 1997 (State Bldg. Code, WAC Ch. 51-42) NEC 1999 [Laws, Rules & Reg. for Installing El. Wires & Equip. (WAC) 296-46]7 UFC 1997 (State Bldg. Code, WAC Chapter 51-44 and 51-45)7 Wash. State Energy Code (State Bldg. Code, WAC Chapter 51-11)
WV8 IPC 1995 (State Bldg. Code) IMC 1996 (State Bldg. Code) NEC 1996, (W. Va. State Fire Code) NFPA 101, 1997 [W. Va. State Fire Code (29-3-5)] NECC 1993 (State Bldg. Code)
WI8 Wis. Administrative Code, Chapters 81-86 Wis. Administrative Code, Chapters 45-64 NEC 1996 (Wis. Administrative Code, Ch. 16-18) Wis. Administrative Code, Chapter 14 Wis. Administrative Code, Chapter 63
WY UPC 1997, no amendments7 UMC 1997, no amendments23 NEC 1999, no amendments7 UFC 1997, no amendments23 N/A
Source: Buildingteam.com. ©2001 Cahners Business Information
NOTES
1 - Applies to state-owned buildings, schools, hotels and theaters.
2 - Applies to all buildings except federal properties.
3 - Applies to state-owned buildings over 4,000 square feet.
4 - Mandatory for state-owned buildings.
5 - Mandatory for state-funded residential and community-owned buildings.
6 - Applies to state buildings.
7 - Applies as a mandatory statewide minimum for all buildings.
8 - Applies as a mandatory statewide code.
9 - Applies to hotels, motels and multifamily dwellings.
10 - Applies to all buildings except single family dwellings.
11 - Mandatory for all commercial buildings.
12 - Applies as a mandatory minimum for all buildings except one-and two-family dwellings.
13 - Applies to all commercial and high-rise residential buildings.
14 - Applies to schools and health-care facilities.
15 - Applies as a mandatory minimum to state-owned buildings, public buildings and buildings over 75 feet high.
16 - Applies to all commercial and residential construction.
17 - Applies to commercial and industrial buildings over 4,000 square feet.
18 - Applies to commercial construction.
19 - Applies to schools, day-care centers and state-owned buildings.
20 - Applies to residential construction.
21 - Applies to hospitals.
22 - Applies to all buildings connected to a public water supply or sewer.
23 - Applies to hotels/motels, restaurants, schools, state-owned and and publicly-funded buildings.
ABBREVIATIONS
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers
IEC - Illuminating Engineering Society
IECC - Int. Energy Conservation Code
IMC - International Mechanical Code
IPC - International Plumbing Code
MEC - Model Energy Code
NEC - National Electrical Code
NFPA - National Fire Protection Association
NFPC - National Fire Prevention Code
NMC - National Mechanical Code
NPC - National Plumbing Code
NSPC - National Standard Plumbing Code
SFPC - Standard Fire Prevention Code
SMC - Standard Mechanical Code
SPC - Standard Plumbing Code
UBC - Uniform Building Code
UFC - Uniform Fire Code
UMC - Uniform Mechanical Code
UPC - Uniform Plumbing Code

 

ASHRAE Forms Code-Development Committee

In an effort to increase the impact that American Society of Heating, Refrigerating and Air-Conditioning Engineer (ASHRAE) members can have on the formation of model building codes, a new group—the Code Development Committee—has recently been created.

"People have been frustrated that ASHRAE hasn't been able to have more influence, but this new code committee will now accept building-codes proposals from ASHRAE members and then propose them through ASHRAE," explains Bruce Wilcox, P.E., chairman of the Code Interaction subcommittee.

In addition to providing consensus recommendations for code changes, the committee has been established to review and take positions on code revisions proposed to the model codes by other groups, according to Bruce Hunn, ASHRAE's director of technology.

Email
Print
Reprint
Learn RSS

Talkback

We would love your feedback!

Post a comment

» VIEW ALL TALKBACK THREADS

Related Content

Related Content

 

By This Author



SPONSORED LINKS

 
Advertisement
Sponsored Links

More Content

  • Blogs

Blogs


Sorry, no blogs are active for this topic.

» VIEW ALL BLOGS RSS

Advertisements





NEWSLETTERS
Plug in and get the latest CSE news, trends and industry updates delivered directly to your inbox!

Green Scene
CSE Codes & Standards
CSE NewsWatch
CSE Fire and Life Safety Solutions
CSE Business of Engineering Management Report
CSE Electrical Solutions
CSE HVAC Solutions
Pure Power
CSE Product Showcase
©2008 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy
Please visit these other Reed Business sites