Life safety in overdrive

Instead of specifying individual systems for fire alarm systems, engine test cell fire suppression, hazardous gas detection, medical emergencies, digital voice command, and emergency weather monitoring, the decision was made to tie everything together into one central network.

Information provided by General Motors and Honeywell.

05/18/2012


Safety is an overriding priority for General Motors (GM), especially at its 45,000-sq-ft engine testing facility in Indianapolis. Instead of specifying individual systems for fire alarm systems, engine test cell fire suppression, hazardous gas detection, medical emergencies, digital voice command (DVC), and emergency weather monitoring, the decision was made to tie everything together into one central network designed by 3S Incorporated.

Numerous notifications

ONYX Series of fire alarm and digital voice command control panels from NOTIFIER feature a modular design and high-level programming capabilities, enabling these systems to be customized to the fire protection and emergency communications requirements of virtually any facility. Courtesy: Honeywell

A NOTIFIER by Honeywell NFS-3030 fire alarm panel serves as the central control unit of the facility’s fire and emergency notification network. This master control is housed inside a sealed, NEMA Type 12 enclosure measuring 7 ft tall and 6 ft wide.

Throughout the building, blue, wall-mounted LEDs indicate the location of medical emergency pushbuttons. When a button is depressed, blue strobe lights actuate throughout the building, and a preprogrammed voice announcement is heard over the network’s speakers, indicating a medical emergency and its location. The system automatically summons an ambulance via a telephone call to a third-party central monitoring station.

The 3S team ensured the design and commissioning of this system met the requirements of NFPA 72: National Fire Alarm and Signaling Code. Given the facility’s open spaces, particularly around the engine test cells, synchronization of strobes for fire, weather, or medical emergency alerts was a huge challenge to comply with both National Fire Protection Assn. (NFPA) and Americans with Disabilities Act (ADA) requirements.

Using fiber optic cables, which are almost impervious to damage caused by power surges, lightning strikes, and other weather-related events, 3S was able to extend the network’s DVC, weather system, and emergency medical stations to two other buildings on the GM campus. To make use of the fire alarm network’s array of speakers throughout the plant, authorized users can utilize the DVC for general, day-to-day public address announcements.

Detection and suppression

In accordance with NFPA 750: Standard on Water Mist Fire Protection Systems, the test cells are equipped with a water mist system, which can be discharged immediately when activated by flame or heat detectors. The system discharges a homogenous suspension of water in nitrogen into the room, but the actual water is dispensed at a rate of ¾ gal/min for 4 min. This is a significant benefit in terms of reducing damage to both the test cell equipment and the product in test.

The water mist system is a twin-fluid system, meaning the nitrogen and water are piped separately to the emitters in the hazard area. It uses a captured water supply housed in a lined tank built for the project.

Test cells are also equipped with an automatic sprinkler system. Its flow and tamper switches are monitored by the NFS-3030 fire alarm control panel.

Gasoline and diesel engines are operated within some of the test cells. To protect operators from abnormal emissions, hazardous gas detection systems from Honeywell Analytics are used to sense carbon monoxide (CO), gaseous hydrocarbons, and refrigerants. The fire protection system also monitors critical exhaust ventilation systems to ensure they remain in operation.

Monitoring configuration

The Indianapolis plant has three NOTIFIER by Honeywell ONYXWorks graphic displays that report the entire network’s status and all events. The ONYXWorks workstations include monitored point-of-use bypass switches to be used when a system requires maintenance, such as when welding needs to be done in one of the test cells.


Information provided by General Motors and Honeywell.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.