Generating Power On Site

Natural-gas-fueled genset is a 1,200-rpm 60-Hz package that delivers 1.6 MW from an electronically controlled, 20-cylinder advanced lean-burn gas engine, coupled with a six-pole synchronous generator. Mechanical efficiency is rated at 43.5%, with fuel consumption at 6,069 BTU/bhp-hr, and NOx emissions at 1.

By Staff

11/01/2003


Natural-gas-fueled genset is a 1,200-rpm 60-Hz package that delivers 1.6 MW from an electronically controlled, 20-cylinder advanced lean-burn gas engine, coupled with a six-pole synchronous generator. Mechanical efficiency is rated at 43.5%, with fuel consumption at 6,069 BTU/bhp-hr, and NOx emissions at 1.0 g/bhp-hr. (by Caterpillar)

Lean-burn gensets are 1,600/1,400-kW natural-gas-fired models that boast high fuel efficiency and low exhaust emissions. Each unit features a 16-cylinder engine operating at either 1,500 rpm or 1,800 rpm and is designed for extended maintenance intervals. (1400 and 1600 GQKA by Cummins Power Generation)

Bi-fuel engine generators are rated at 300 kW and 375 kW output. These standby models are capable of operating on 90% natural gas and 10% diesel fuel. Both models are to be offered as elements in a modular power system or as twin sets in a single 600-kW or 750-kW package. (by Generac)

Genset provides a 1,500-kW generator in a 20-ft. ISO container. Four-cycle turbocharged diesel engine features liquid drain ports and filters that are quickly accessible for easy maintenance. Fully insulated container uses a reactive temperature control with dual fans, as well as a vertically mounted radiator that is shock- and vibration-isolated. (by MQ Power)

Power center combines service equipment and generator-transfer equipment in the same unit, allowing for easier generator installation in multi-panel applications. Units are installed next to exterior utility meters and can be paired with generators ranging from 5 kW to 30 kW and are available in 12- or 16-circuit configurations. (by Gen/Tran Corp.)

Turbine Generators are designed for steam and gas turbine applications. Specifications include the following: a power rating of 3.5 to 8.5 MW; voltage of up to 15 kV; a weight of 36,000 lbs. (8.5 MW unit); and frequency of 60 Hz or 50 Hz (at 5/6 voltage and kVA), three phase. (by Kato Engineering)

Motor/Generator uses a patented technology to provide the ride-through of a traditional backup system but without batteries. On utility power, the motor drives the generator mechanically. The electrically isolated generator delivers continuous, clean power. During ride-through, inertial energy drives the generator, which delivers constant frequency and regulated voltage, typically 12 seconds at full load. (by Precise Power)





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.