A developer’s guide to condominiums and risk mitigation

See four common causes of condominium litigation.

The increase in demand for the condominium experience entices more and more developers to contemplate starting their own condo projects.  If you are one of them, keep in mind that condo construction comes with a marked increase in litigation risk for the design, development, and construction teams involved. These claims range anywhere from contract disputes to professional malpractice. It is possible to minimize this risk and ensure a successful project, but it’s a good idea to review some of the condominium guidelines and regulations to watch for during the design and building process.

Four common causes of condominium litigation

Multi-family industry experts agree that while apartment complexes come with a high chance of litigation, the risk is even higher with condominium developments. Individual owners and Homeowner Associations (HOAs) file disputes for numerous reasons, including odors, leaks,  cracks, and equipment defects. In many cases, these claims are meritless, but that does not dismiss the cost of dealing with them in the first place. By doing proper due diligence, architects, developers, and general contractors can significantly reduce their chances of finding themselves in the middle of a lawsuit. Most legal claims fall into one of four main categories:

Construction defects

Many of these lawsuits revolve around construction defects in commonly owned elements or undivided portions of the unit, such as the roof, driveway, or building exterior. The suits are usually based on breach of express, negligence, or an implied or statutory warranty.

Contract disputes

Disparities overpayment and performance or non-performance are probably the most common contract disputes that wind up in litigation. However, you will find that warranty claims, indemnification claims, and other contract-based claims are also prevalent.

Professional malpractice

Architects, engineers, and others involved in a condominium construction project are all open to malpractice suits. Substandard service that leads to structural problems or other issues opens the opportunity for associations to seek retribution for professional malpractice.

Implied warranties

Every condominium project includes contractual warranties, but they may be subject to certain implied warranties, as well. Assuming that these implied warranties have not been validly disclaimed (which is not always a safe assumption), they can provide additional causes for action by condo associations.

A robust design

Ensuring that you have a top-notch condo design lowers the risk of a claim or litigation. The overall intent of the entire team (developer, designers, contractors) should be to create a structure of the highest quality, and the process should be as transparent as possible. The design team should avoid making assumptions and present all options to the developer.  The developer must be comfortable making well-informed decisions, such as whether or not to bring in additional equipment or incorporate higher-end materials and aesthetics.

Some items that need to be at the forefront of consideration are those relating to occupant comfort and the human senses. This includes anything that affects smell, temperature, lighting, water, taste, feeling, and sight. It is well known that mechanical, electrical, and plumbing systems can significantly affect the occupant’s condo experience within the building. Additional attention applied to these areas can keep occupants happy, and happy occupants tend to not file complaints. Also, some of the most common issues brought up in condo litigation are water leakage and sound transmission. It’s in the developer’s best interest to pay particular attention to these areas as much as possible during the design phase.

Premium level of service

As detailed below under Design & Quality Control, a more robust design and documentation process, and added attention to detail coupled with the additional risk of condominium liabilities, requires more time from experienced senior staff on the condo engineering team. It should be noted that the required experience level of senior staff and the extra effort of all involved in the project will result in an above-average labor cost. But this cost is justified in the level of care and commissioning required for the project.

Defining terms an conditions-Insurance policies

Having a good condo MEP engineering firm on your side goes a long way towards reducing condo litigation risk. While there are ways to reduce the likelihood of litigation, you cannot completely eliminate it. Some law firms target the construction industry specifically to file expensive lawsuits for insurance companies to settle. So, more likely than not, a claim will come up against a developer. When this happens, it pulls the entire condominium design team in, as well.

Because of this increased risk of litigation, Jordan & Skala Engineers recommends having a comprehensive, project-specific insurance policy in place to give some financial protection for the whole team. This type of insurance policy is usually called a “wrap.” An owner-controlled wrap policy covers all parties involved in the project under one umbrella.

Defining terms and conditions- Contractual items

Making sure you have broad contractual items within the Terms and Conditions in place when quoting a project gives you a great deal of protection. Consider including the following:

  • Ensure that the HOA  is contractually required to have a two-thirds vote from tenants before bringing a claim.
  • Structure contracts to preclude claims against the condo design and construction teams for issues related to anything constructed or implemented against their written recommendations.
  • Enact time limits for bringing specific claims against the project. Time limits can avoid frivolous lawsuit filings from being brought just as any Statute of Limitations is due to expire.
  • Request that all prospective condo buyers have their unit inspected by a qualified professional prior to purchase and agree to accept the unit “as-is.” Any issues that arise during the inspection will be fixed before closing.

Once the Developer finalizes the Terms and Conditions, all project partners should review the contracts and make sure they understand each other’s roles and scopes of work.

Proper documentation

The value of proper documentation cannot be overstated. Having the supporting documents to back up decisions made will prove invaluable when dealing with condominium liabilities. The Developer should well document every aspect of every phase of construction. Jordan & Skala highly recommends an increased level of quality control, such as:

Having a stringent documentation process will help you sufficiently vet essential items throughout all phases of construction. Things to pay special attention to include:

A favorable location and strong workforce

Where you decide to build can be a critical factor in the overall quality of your project. For example, highly qualified labor can be difficult to find in coastal areas or small towns located outside of an urban area. Unfortunately, unskilled labor often results in poor workmanship. All contractors should be thoroughly vetted and their references checked. Quality of workmanship becomes even more important if the location has a challenging environment.

For example, coastal and tropical climates can place undue stress on the HVAC systems and building envelope for condos due to high humidity. If the condominium is located in a high seismic zone, it is at an increased risk of structural cracks, leaks, and cosmetic damage. Seismic activity can also cause windows and doors to shift, leaving the building vulnerable to water infiltration. These are precisely the types of things that can move an HOA or condo association to action in an attempt to recoup their repair costs.

Another thing to consider is that resort locations or areas with mostly seasonal occupancies have tenants who leave their units unoccupied for long periods. These well-meaning occupants often turn off their HVAC systems or leave them in a state detrimental to their units’ long-term condition. This can result in mold and other damage, which is highly likely to lead to damage claims.

Design and quality control

During a condo construction project, it’s good to increase the number of site visits and implement a higher level of coordination and design whenever possible. These projects often merit a premium fee because it is time-consuming to achieve risk mitigation for condos. The following are our suggestions for what to focus on:

  • Hiring a skilled, qualified general contractor that you can trust. Doing so allows for adequate delegation and creativity through design and construction.
  • Documenting the contractor’s work as much as possible. One technique that has grown in popularity is to use photographic and video documentation throughout the construction process. For example, a Developer might take photos of every window and door’s waterproofing elements before they are covered up. Having these photos on hand could be a critical piece of evidence in a defect lawsuit brought on later.
  • All waterproofing and acoustical specifications should be recommended and implemented by a qualified contractor or consultant.
  • Collaborating with all fire protection professionals on occupant safety. Fires pose a significant risk and can quickly turn into lawsuits.
  • On projects where testing is required by certain building codes, testing for duct tightness and envelope pressurization on all units.
  • Submitting the condo architecture and engineering drawings for peer review. Having a second or third pair of eyes on your plans allows an independent architect or engineer the opportunity to review them for errors or points of improvement.

The risk of many units

It’s the law of averages, but the greater the number of units you have, the more opportunities for design or construction problems to arise. You can minimize this risk by using a qualified team to thoroughly inspect all units throughout each phase of construction. Many claims are related to construction defects, so it’s imperative that developers work only with experienced architects who include flashing, penetration, and waterproofing details specific to residential condos in their plans.Once construction is complete, create a maintenance manual and transfer it to the condo association.

Prepare for testing, maintenance and repairs

Don’t find yourself at the mercy of an inadequate budget. Lack of funds often drives developers and contractors to cut costs instead of adopting the best practice or opting for a better-designed system that is more in line with a condominium project’s rigorous demands. This lack of foresight often leads to system failures and leaves developers open to litigation. It’s also a good idea to review all marketing materials to ensure the brand message sets realistic expectations. Working through condominium construction is never the ideal time to cut corners on any part of the project.

 

This article originally appeared on Jordan & Skala’s website. Jordan & Skala Engineers is a content partner of CFE Media.

By

Ben Weissman, PE

Ben Weissman, PE, principal, Jordan & Skala Engineers