RDK Engineers: Brown Brothers Harriman and Co.

Existing building retrofit at an office building.

08/14/2014


Engineering firm: RDK Engineers
2014 MEP Giants rank: 27
Project: Brown Brothers Harriman & Co.
Address: Boston, Mass., U.S.
Building type: Office building
Project type: Existing building retrofit
Engineering services: Automation/controls, electrical/power, fire/life safety, HVAC/mechanical, energy/sustainability, plumbing/piping, and other
Project timeline: 6/19/2012 to 10/1/2013

Challenges

The entire space was considered a mission critical facility that required design of infrastructure so the entire office could be on a backup generator. The space also required design of a full-service cooking kitchen in a high-rise building to accommodate 900 employees. In addition, all MEP systems, controls, and ductwork had to be designed new from scratch on all floors. Finally, the project had to be completed in a tight time frame, an 8-month construction period.

Solutions

There was not enough space in the building to add an additional generator to back up all the systems in the new space, so an intricate electrical infrastructure was designed where power is diverted by priority to equipment in the event of an outage. To give the client its full-service cooking kitchen, RDK designed an HVAC system to bring make-up air and exhaust up through the building by using an abandoned elevator shaft. Last, the client wanted a floating ceiling. Ductwork and piping was kept as hidden as possible and various fan power boxes were bench tested to find the quietest equipment to ease acoustical concerns.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me