NYC landmark open with integrated engineering systems

Buro Happold provided structural engineering, MEP engineering, lighting design, and fabrication modeling for the New Amsterdam Plein and Pavilion that commemorates New York City's Dutch founders.

Source: Buro Happold

05/13/2011


Buro Happold has welcomed the New Amsterdam Plein and Pavilion, a public structure that celebrates New York City’s Dutch heritage, which formally opened to the public on Thursday, May 12th, 2011. Located in Peter Minuit Plaza next to Manhattan’s Battery Park, the landmark was made possible through a grant from the Netherlands government to celebrate the 400th anniversary of the founding of New Amsterdam. The structure was unveiled in 2009. Its visitor’s information center and a café open to the public for the first time on Thursday.

Buro Happold collaborated with Handel Architects (Architect of Record) and UNStudio (Design Architect/Executive Architect) to design the windmill-shaped structure. Its standout features include:

  • The structure is made of durable, low-maintenance steel and plywood that is covered with a flexible wood fiber surface and coated with Polyurea, a material that is used in the production of spandex, to create a smooth and seamless surface;
  • The fully-integrated structural, MEP systems, and lighting fixtures are concealed in the structure’s shell;
  • The interior is naturally ventilated through shading fins that allow hot air to escape, but guard against rain, and reduce the need for air conditioning and heating;
  • The structural components were designed and produced using a file-to-factory process where computer-controlled machines use digital files to cut and assemble the structural components;
  • An interactive touch screen projection imaging system balances a double-layer dynamic LED lighting system, which allows the glass exterior walls to change colors and glow at night.

- Edited by Amanda McLeman, Consulting-Specifying Engineer, www.csemag.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.