AHA Consulting Engineers Inc.: Primerica

New construction of a data center, office building.

08/14/2014


Data center. Courtesy: AHA Consulting Engineers Inc.Engineering firm: AHA Consulting Engineers Inc.
2014 MEP Giants rank: 51
Project: Primerica
Address: Duluth, Ga., U.S.
Building type: Data center, Office building
Project type: New construction
Engineering services: Automation/controls, commissioning/retro-commissioning, electrical/power, fire/life safety, HVAC/mechanical, lighting, energy/sustainability, plumbing/piping, and other
Project timeline: 9/16/2011 to 7/17/2013
MEP/FP budget: $365,000

Challenges

The project presented many challenges. The process of juggling concurrent core and shell design with interior design while maintaining budget and schedule was particularly challenging. But multiple coordination meetings (both face-to-face and by web meetings) allowed the engineering team to blend well with the other team members and clients. Design challenges included the blending of a television recording studio, a mission critical data center, and a 200-seat full-service cafeteria into a corporate office environment. The project is the corporate headquarters for the client, and all systems needed to be both dedicated to the use and yet blend together as one cohesive operation.

Aerial photo of the building (350,000-sq-ft building). Courtesy: AHA Consulting Engineers Inc.Solutions

The firm’s deep experience in design of all the project occupancies and applications, coupled with a dedicated team working in step with the architects, designers, and other team consultants, allowed the multiple facets of the project to blend into a common goal for all. Multiple (sometimes daily) face-to-face and web meetings allowed the team to be in sync with all players. It was critical that all stakeholders, including owners, clients and contractors, were involved to speak to scope, schedule, and budget. The design of the TV studio required understanding of acoustics and vibration as well as the need for separating the systems from the office core. Working with specific consultants and a collaborative give-and-take approach by all team members resulted in a state-of-the-art studio. The firm’s experience in data center design for multiple clients allowed it to provide a reliable mission critical data center. The systems had to be designed without interlocking with the base building systems while residing within the same structure.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me