Your questions answered: In the Zone of Applying Zone Selective Interlocking (ZSI)

The Aug. 30, 2018, “In the Zone of Applying Zone Selective Interlocking (ZSI)” webcast presenter addressed questions not covered during the live event.

09/06/2018


Zone selective interlocking (ZSI) has existed for more than 40 years, yet so many people in the electrical field have little knowledge about what it is and how it works. ZSI is a network of two or more interconnected circuit breakers that communicate with each other so that a short circuit or ground fault will be cleared by the breaker closest to the fault in the minimum time possible. The primary goal of ZSI is to switch off the fault current within the shortest possible time under consideration of full selectivity, regardless of the fault location in an electrical distribution system.

ZSI provides the complete range of selectivity with an extremely short delay time of 50 milliseconds minimum typically regardless of the number of fault zones and the location of the short circuit or ground fault in the power distribution system. The benefits of ZSI become more apparent with a higher number of fault zones typically found in large systems. By shortening the time to clear the fault, ZSI significantly reduces stress and damage in the event of a short circuit in the electrical apparatus. As described in NFPA 70-2017: National Electrical Code (NEC) Article 240.87, ZSI also is a method suitable for compliance with that section of the code.

Key topics include:

  • Applying ZSI in arc reduction and selective coordination circuits.
  • How breakers communicate and connect in a ZSI network.
  • Illustrations and comparisons of ZSI with time current curves.
  • Understanding the fault protection sequences of ZSI.
  • General cost impact.

Presenters during the webcast were:

  • Rick Pinchard, business development manager, Siemens
  • Roy Hicks IV, business developer, Siemens
  • Robert W. Jensen, P.E., business development manager, Siemens.

Roy Hicks IV, SiemensPresenter Roy Hicks IV, business developer, Siemens, responded to questions not answered during the live In the Zone of Applying Zone Selective Interlocking (ZSI) webcast on Aug. 30, 2018.

Question: Time delay options may include instantaneous, inverse, or very inverse. Would time delay increase result in slower clearing time and greater incident energy?

Roy Hicks: Yes. Time delays increase incident energy level. Zone selective interlocking (ZSI) is dedicated to a consistent ZSI delay that is slower than instantaneous but faster than short time delay.

Q: How does the cost of ZSI installation compare to the cost of a maintenance switch installation?

Hicks: That’s somewhat hard to say. If the maintenance switch is remote, touch, proximity, etc., and if the ZSI input/output (I/O) is all factory wired inside the gear or if portions of it will be wired between gear.

Q: Explain again why you want instantaneous under the available arcing current (AAC).

Hicks: You may want a non-ZSI downstream breaker to trip before the 50 millisecond ZSI upstream breaker for coordination. If you do, then lowering the instantaneous below the AAC will allow coordination with an upstream ZSI breaker.


<< First < Previous Page 1 Page 2 Next > Last >>

Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me