Infrastructure for hydronic heating, cooling

Taco’s LoadMatch is an advanced infrastructure that enables efficient hydronic heating and cooling.

09/30/2011


Taco’s LoadMatch is an advanced infrastructure that enables efficient hydronic heating and cooling while delivering better comfort and reduced energy consumption. A LoadMatch system also reduces design, start-up, and commissioning time. LoadMatch is the marriage of two old ideas—single-pipe distribution and primary-second pumping—wrapped around a new technology. The technology consists of maintenance-free, wet rotor circulators. The primary distribution system is a single-pipe loop; the secondary distribution system is a decoupled secondary piping loop for each terminal unit with flow delivered by a dedicated circulator. A LoadMatch single pipe uses small, low kW circulators that deliver water, on demand, to terminal units. The simplicity of LoadMatch permits the use of one size of pipe for large portions of the system. In single-loop installations, there is no limit to the number of terminal units that can be installed.

http://commercial.taco-hvac.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me