SEARCH Archives
Loading
Sponsored by:

Contact-cooled air compressor

The R-Series 55 to 75 kW/75 to 100 hp contact-cooled air compressors from Ingersoll Rand are available.

01/30/2012


The R-Series 55 to 75 kW/75 to 100 hp contact-cooled air compressors from Ingersoll Rand are available in fixed-speed and variable speed drives at capacities up to 114 to 479 cfm. The line offers a total air system dryer and filtration option providing clean, dry air in a single package, minimizing installation costs and footprint while allowing single-point maintenance and monitoring for the complete system. The R-Series also boasts the Progressive Adaptive Control filtration and temperature monitoring system, stainless steel V-Shield, and sequential cooling technologies previously introduced with the larger 90 to 160 kW/125 to 200 hp range. These features are designed to maximize reliability and productivity while helping reduce maintenance costs.

www.ingersollrand.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.