Power Generation/ Emergency Power FINALISTS

06/28/2005


Bi-Fuel Standby Generator by Generac Power Systems
Bi-fuel standby generator has output ratings of 300 or 375 kW and can operate on up to 90% natural gas and 10% diesel fuel. Reduced consumption of diesel fuel under bi-fuel operation leads to significantly longer run times per tank of fuel, according to the manufacturer. The generator uses a method called combustion air gas integration, which introduces the proper amount of natural gas to the intake air prior to the turbocharger and takes advantage of the precision and response of the microprocessor controlling the mixture. As such, it responds instantly to an array of inputs, ensuring optimal performance regardless of the changing conditions. Additionally, knock sensors continually monitor internal combustion and detect the onset of engine knock before it occurs, thus preventing potential damage to internal components.
www.generac.com


 


STS2/PDU by Liebert
Static transfer switch provides an automatic, seamless transfer between a critical load and the outputs of two independent uninterruptible power supply systems in a dual-bus configuration. If the primary UPS fails, the switch automatically transfers the loads to the secondary UPS. The switch has triple-redundant logic, and each DSP controller is capable of working independently, in addition to monitoring the other two. If one malfunctions, the other two lock it out, and each controller has power feeds from both power supplies. All mechanical and electronic components are accessible from the front of the unit, allowing for more freedom in system design, ease of installation and service, and less floor space required for maintenance access. Additionally, the unit uses an internal CANBUS protocol for high-bandwidth communication. www.liebert.com


1600EP Series by Toshiba
Uninterruptible power systems are true on-line, double-conversion units that feature hot-swappable battery packs and cooling fans,to 65 Hz and 0.85 output power factor. Overload capacity is 150% for 10 seconds, 125% for 10 minutes and 1,000% for one cycle. www.tic.toshiba.com


 





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me