HVAC FINALISTS

06/28/2005


Fan Coil UVC Kit by Steril-Aire
Fan coil UVC kit contains all the components needed to retrofit fan coils with germicidal lights that produce ultraviolet radiation in the “C” band—200 to 280 nanometers. Fan coils have been identified as a primary source of mold and other indoor air quality problems. Many are currently equipped with low-efficiency filters that do not capture infectious disease particulates or mold. Another problem is that many of the UVC devices on the market are not sized to fit fan coils. This kit is available in a choice of six lengths and attachment accessories. The manufacturer claims that it has been independently tested to deliver five times the output of other UVC devices under typical HVAC operating conditions of 45
www.steril-aire.com




Frictionless Centrifugal Compressor
Chiller by McQuay International
Frictionless centrifugal chiller eliminates the high friction and maintenance-intensive oil management associated with oil-lubricated compressor bearings by using an oil-free magnetic-bearing compressor. The frictionless compressors offer increased efficiency with decreased operating noise. Part-load performance is as low as 0.375 kW/ton IPLV with integral variable-speed drives. The full-load performance is as low as 0.62 kW/ton. Dual compressors on a single refrigerant circuit add further to the part-load efficiency.
As for noise, the compressor has sound-pressure ratings as low as 77dBA per ASHRAE Standard 575, and the chiller itself features a direct-drive design that eliminates gear noise. The chiller’s digital controls are said to be easily integrated with building automation systems using BACnet, LonMark or Modbus protocols. Control strategies include automatic control of chiller-water and condenser-water pumps, control of up to four stages of tower fans and modulation of tower fan or bypass valve. www.mcquay.com


City Multi R2-Series Variable Refrigerant Flow
Zoning System by Mitsubishi Electric

Variable refrigerant flow zoning system is a two-pipe system that cools and heats simultaneously, said to be the first commercially available in the United States. At the heart of the system is an inverter technology that relies on a variable-speed compressor to deliver precise amounts of heating or cooling to individual zones. The system is fully integrated using direct-digital control to tie together an outdoor unit with branch circuit controller, indoor units and remote and central controllers. Two outdoor models are offered: 80,000-BTU/h with up to 15 connectable indoor units; and 100,000-BTU/h with 16 connectable indoor units. Three different indoor models are offered. Both systems can be either ducted or ductless.
Individual zone control is made possible through an assortment of remote controllers. Multiple systems can be controlled and monitored by tying them together with a centralized controller to link together as many as 2,000 units. www.mrslim.com








No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me