The Raid on Refrigerants

12/21/2004


By Barbara Horwitz-Bennett
Contributing Editor

Editor’s Note: The following observations on refrigerants come from the participants in CSE’s 12/04 M/E Roundtable, which discusses hybrid chiller plants. Look for it soon, along with the rest of our December issue, at www.csemag.com .

When it comes to choosing a refrigerant for chillers, what factors go into play?

“Of the two primary new refrigerants, R123 and R134a, one is slightly better for reducing ozone depletion and the other is slightly better for reducing global warming. But in reality, we are splitting hairs. Both refrigerants are significantly better for the environment at a slight penalty to efficiency,” explains Ken Clark, P.E., principal and project manager, Burns & McDonnell Engineering, Kansas City, Mo.

More specifically, the low-pressure refrigerant R123 offers slightly higher efficiencies, but has an ozone depletion factor, while R134A is a high-pressure refrigerant with a high global warming factor, according to Pete Zak, P.E., principal, M/E/P group manager, Graef, Anhalt, Schloemer & Associates, Inc., Milwaukee. However, Zak adds that with R134A, “we have found this to require larger machines, which may or may not be competitive with low-pressure machines.”

Zak also mentions refrigerant blends as an alternative choice. “Refrigerant blends use a combination of environmentally acceptable refrigerants and present a high efficiency. They work well, but owners are hesitant to buy into something less familiar,” he explains.

According to Milton Meckler, P.E., CPC, president, Design Build Systems, Los Angeles, approaching things from a life cycle standpoint is best.

“Assuming that there is an established given ratio of hybrid gas to electric capacity, a longer term, i.e., 15-20 year view, when trading off performance efficiency vs. environmental impact is preferred,” says Meckler.

However, Meckler also posits that personal choice on the part of building owners may eventually give way to regional regulations arising from continuing global warming concerns.

At the same time, Clark bemoans the phasing out of R22. “The real tragedy is that R22 will be lost as a refrigerant in the future. This is an efficient refrigerant that has served the air-conditioning and refrigeration industry well for decades,” he laments. “But now the industry has to change at significant expense to the economy because it is slightly less desirable for the environment over the new refrigerants.”





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me