SEARCH Archives
Loading
Sponsored by:

Next-generation energy modeling

Since 2001, the DOE has released the energy modeling calculation engine called EnergyPlus as a new generation flagship tool meant to combine the best features of the multiple previous tools funded through the federal government.

Erin McConahey, PE, Arup, Los Angeles

09/24/2012


On the Simergy main building creation screen, users can create basic building shapes, select floor height, and choose other building options. On other screens, the user can select thermal zones or determine window glazing. Courtesy: Simergy, beta versionSince 2001, the DOE has released the energy modeling calculation engine called EnergyPlus as a new generation flagship tool meant to combine the best features of the multiple previous tools funded through the federal government. In the past, the DOE has generally released a public domain engine and allowed third-party developers to create interfaces; however, there has been limited uptake as the more familiar DOE-2 based software is still generally acceptable for energy code compliance. Therefore, the DOE and the California Energy Commission have invested in the development of a new graphical user interface called “Simergy” to be released to the public in late 2012 with the intention that the interface will be so user-friendly that it will help to greatly increase the ease-of-use accessibility of energy modeling for the industry.

Editor’s note: The author has been on the beta testing team for Simergy and has been given permission to include a preview of the new software in this article. The software design team at Lawrence Berkeley National Laboratory has engaged with HVAC and architectural industry professionals for the past five years to develop interfaces that allow the easy and quick generation of models. Time-saving features include the following:

  • Pre-set building geometries in the rectangular, L-shape, U-shape, H-shape, T-shape, and cross-shape configurations are available with automated zoning of perimeter versus interior as per best practice energy modeling in less than a minute, inclusive of automatic unique space naming. In the first release, there are additional freeform tools available to import *.dwg files and trace over them to create building geometry, and eventually it should be possible to import whole BIM models to create geometry. All auto-generated zoning is visible in a BIM embedded within the program for visual cross-reference. (See Figure 4.)
  • The use of drag-and-drop techniques to create thermal zone groupings allows the wholesale assignment of internal load, temperature control, and building construction templates.
  • Similarly, the use of drag-and-drop HVAC components into airflow and water loop system templates allows the user to exactly match the component order and control intention of the original design.

 

 

In addition to these process optimizations, access to the EnergyPlus engine itself opens the doors for an engineer to model natural ventilation, thermal mass, chilled beams, underfloor air distribution systems, thermal stratification, radiant floor systems, ground coupled heat exchange systems, renewable energy devices, and thermal storage devices, along with the pre-set “template” examples for the more traditional HVAC systems.

 

Software packages

The most prevalent commercially available energy modeling software packages are:

Equipment manufacturers’ load analysis programs

 

Trane’s TRACE
Carrier’s HAP

 

Independent energy modeling programs

 

Integrated Environmental Solutions (IES)

 

Integrated with BIM software

 

Autodesk Ecotect and Green Building Studio

Bentley  AECOsim

 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.