View All Why are fire and life safety systems vital?
What to look for in NFPA 72-2022
This article is a look at some of the significant changes that may be included in the 2022 edition of NFPA 72
Understanding fire pumps, their applications and sizing
Learn about fire pump types, drivers, sizing and components
Implementing 2019 NFPA 110
The 2019 edition of NFPA 110: Standard for Emergency and Standby Power Systems includes a variety of revisions and updates that clarify design
Interpreting revisions to NFPA 13-2019
Know how to navigate the restructured NFPA 13 sprinkler standard and understand technical changes
Illuminating the means of egress
Differentiating the requirements of egress lighting versus emergency egress lighting requires a close look at several codes and standards
How egress is planned using NFPA 101
NFPA 101: Life Safety Code is one of the primary sources for the requirements of exit pathways
NFPA 20: Fire pump design
When designing a fire pump, there are a number of factors to keep in mind, particularly NFPA 20
Your questions answered: Fire and life safety: Notification and communications systems
Questions not answered during the live “Fire and life safety: Notification and communications systems” webcast Oct. 30, 2019, are answered by the presenters
What is a unified mass notification ecosystem?
Fire and life safety professionals need to leverage notification assets to get the emergency message out to the affected group as soon as possible
What’s new in NFPA 72?
The 2019 update of NFPA 72 provides fire protection engineers, along with other engineering professionals, improved mass notification and emergency communication guidelines.
How to design fire alarm notification systems
This mass notification and emergency communication system design discussion is holistic and includes all associated coordination requirements.
Standardizing NFPA 13
NFPA 13-2016 is applicable to all sprinkler system designs and installations, with the exception of sprinkler systems in low-rise residential buildings and one- and two-family dwellings and manufactured homes.
Your questions answered: Critical power: Arc flash mitigation
The Sept. 20, 2018, “Critical power: Arc flash mitigation” webcast presenters addressed questions not covered during the live event.
Selecting pipe and piping materials
Selecting pipe and piping materials involves many factors. Designers should approach these decisions and identify strengths and weaknesses of various pipe materials and connection methods.
The benefits of integrated fire protection and life safety system testing
NFPA 3 and NFPA 4 explore integrated fire protection and life safety system testing and are vital to a building’s overall fire/life safety implementation.
Designing passive and active fire protection systems
Fire protection engineers should consider the building's construction, fire suppression systems, and smoke control when designing active and passive fire protection systems. The International Building Code and NFPA standards provide guidance on passive and active fire protection systems.
How to select a clean agent fire suppression system
Fire protection engineers should understand which clean agent fire suppression system is most appropriate for a mission critical facility.