You Have the Power! (over Ethernet)

Power over Ethernet continues to grow more popular, and many companies have already implemented PoE solutions. So what exactly should consultants know about this new technology? PoE allows the transmission of electrical power over the same Ethernet infrastructure used for data transmission. It extends the capability of the Ethernet infrastructure and delivers power over high-quality category 5e...

04/01/2005


Power over Ethernet continues to grow more popular, and many companies have already implemented PoE solutions. So what exactly should consultants know about this new technology?

PoE allows the transmission of electrical power over the same Ethernet infrastructure used for data transmission. It extends the capability of the Ethernet infrastructure and delivers power over high-quality category 5e/6 data cables, thereby eliminating the need for extraneous power adaptors, power cords and AC outlets.

Applications

The PoE standard, formally known as IEEE 802.3af, was ratified in June 2003. Prior to the adoption of this global standard, most PoE solutions were mutually incompatible proprietary standards. With the new standard in place, a wide array of PoE devices could be developed with some assurance of interoperability.

A variety of interoperable devices have already been introduced. These include Voice over IP (VoIP) phones, wireless local area network (WLAN) access points and security network cameras. The IEEE 802.3af project was driven by the proliferation of low-power devices that need to be connected to local area networks (LANs). Providing power to these network endpoint devices, in addition to the network connection, results in a cost-effective network infrastructure deployment.

Two options

The PoE architecture consists of two elements: the powered device (PD) and power-sourcing equipment (PSE). Two approaches have been adopted to supply power to a link via a PSE. One approach, which supplies power over the signal pairs (end-span), is intended for use by network equipment vendors. Another option is mid-span power insertion over the spare pairs (10BASE-T and 100BASE-TX networks) designed to support the installed base. Initially, the mid-span approach is a lower-cost solution for legacy networks since it will not require the replacement of the network equipment.

Why PoE?

From a financial perspective, PoE holds the allure of cost savings by eliminating the need for installation of electrical outlets by certified electricians. PoE also provides IT managers with the flexibility to deploy networked devices in optimal locations. WLAN access points can be placed behind ceiling tiles, and security cameras can be placed to provide greater coverage without concern for the AC outlet tether. In addition, network management enables IT managers to monitor and manage powered devices remotely.

Providers of PoE also argue that they offer a more reliable power supply to networked devices, with PDs that are less susceptible to power surges, theft, interruption and disconnection.

And as a standards-based solution, PoE offers vendor-independent interoperability as well as backward compatibility with legacy Ethernet infrastructure. An added benefit of the international standard is that devices do not need separate cords and adapters for different countries.

A growing trend

Though PoE-enabled ports today probably make up only a small fraction of the installed port base for Ethernet LAN switches, in the near term, the use of PoE-powered devices will experience rapid growth as IT managers look to add PoE capabilities to their networks.



Potential PoE LAN Devices

Internet protocol (IP) telephony

Web cameras

Wireless access points

Industrial automation

Security access control and monitoring systems

Point-of-sale terminals

Lighting control

Gaming and entertainment equipment

Building management



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me