World’s largest office furniture supplier celebrates 100 years by reducing its energy consumption and carbon footprint

Steelcase meets efficiency and sustainability goals with control system and energy monitoring software solutions.

02/14/2013


The Energy Center at Steelcase’s Grand Rapids, Mich., headquarters.Steelcase celebrated its 100th anniversary in 2012. It also marked 100 years of staying on the cutting edge of the office furniture market. 

Steelcase’s first product, a fireproof wastebasket, was a technological achievement in 1912. In this century, Steelcase leads the way in designing and manufacturing furniture that helps boosts office workers’ productivity by making their work environments both aesthetically pleasing and ergonomically sound. 

Given its track record for innovation, it’s not surprising that Steelcase approached its 100th anniversary looking for ways to build energy-saving measures into its manufacturing processes. Management goals to cut overall energy consumption by 15% in 2011 and to reduce the company’s carbon footprint by 25% during the five years leading up to leading up to its 100th anniversary. 

The following case study tells the full story of how Steelcase met those goals, and continues to improve upon them. 

Background

Success in business is no longer accomplished by producing more products in less time. Improving efficiencies and identifying areas of improvement is the name of the game for best-in-class organizations. Steelcase is no exception. To help maintain its position as the world’s largest office furniture supplier, Steelcase management set aggressive goals for improving the company’s bottom line through improved efficiency and sustainability efforts. The deadline: the company’s 100-year anniversary in 2012.  

“Our business is very competitive,” explained Bruce Reynolds, manager of corporate communications at Steelcase. “To be successful, we have to constantly improve our production practices. The recent recessions emphasized the importance of consistently driving manufacturing efficiencies—driving cost out of production meant savings to our bottom line.” 

Steelcase implemented a new control system to more cost-effectively operate its boilers, and installed energy management software to gain better insight into companywide energy consumption. Due to these and other efforts, the company met all of its efficiency and sustainability goals, including reducing energy consumption by 15% and shrinking its carbon footprint by 25%. 

Challenge

The energy center at Steelcase’s Grand Rapids, Mich., headquarters is home to four boilers (two coal-based and two gas-fired) that produce and distribute steam throughout the manufacturing process areas. “The energy center is truly the lifeblood of our Grand Rapids facility,” explained Eric Newsome, senior automation engineer, Steelcase. “If it goes down, so does production, and with the volume of orders we’re meeting each day, downtime simply isn’t an option.” 

Steelcase operators rely on FactoryTalk View Site Edition human-machine interface software for comprehensive insight into boiler operations at the company’s Energy Center.The reliability required of the boilers left no room for error. Unfortunately, the  existing distributed control system (DCS) running the boilers was more than 25 years old, and locating spare parts had become extremely challenging. Bill Boss, the chief boiler operator at Steelcase, bought used parts wherever he could find them, and whenever a problem arose with the system, he was forced to call in support from the DCS vendor. “It was a black box system that we couldn’t troubleshoot ourselves,” explained Boss. “The vendor had the software tools and the expertise we needed, and whether we had a service contract or paid by the phone call, getting help was becoming prohibitively expensive.” 

In addition to looking at boiler reliability, the company also was evaluating its overall energy monitoring capabilities. Management set goals to reduce energy consumption by 15% in 2011 and to reduce the company’s carbon footprint by 25% during the five years leading up to Steelcase’s 100th anniversary in 2012. 

Management also wanted to comply with ISO-14001. The international standard was designed to help companies identify, control, and improve the environmental impact of their activities and products by implementing a systematic approach to setting and achieving environmental objectives. “A lot of companies require their vendors to be ISO-14001-compliant,” said Reynolds. “Compliance is recognized as a sign of commitment to the environment, and it’s a key part of our strategy for balancing people, planet, and profit.” 

Before making improvements, Steelcase relied on manual data collection practices to monitor water, air, gas, electric, and steam (WAGES) consumption throughout its facilities. “We had one guy responsible for visiting the meters installed on each substation in each building once per month,” explained Newsome, the senior automation engineer. “He wrote down the readings, entered the data into a spreadsheet, then reconciled the utility bills. The process worked fine—until that guy went on vacation.” 

With the primary data collector out of the office, data collection practices changed, resulting in a database filled with skewed information that took weeks to resolve. “We needed a way to automatically gather real-time data so we could identify opportunities for improvement,” said Kay Bolinger, senior facilities engineer, Steelcase. “As our manufacturing infrastructure became leaner and our IT infrastructure expanded, we realized it was time for us to consider a comprehensive WAGES metering strategy.”

Solutions

Steelcase needed a cost-effective control system for its energy center that would be easy for the company to maintain, troubleshoot, and optimize on its own. After reviewing several options, the team ultimately selected the PlantPAx process automation system from Rockwell Automation to replace its existing DCS. “Our engineers were familiar with Rockwell Automation products, which we knew would ease maintenance and troubleshooting,” said Newsome. “Plus, we already had a TechConnect support contract with Rockwell Automation, which provided the added level of service we needed.” 

Rockwell Automation Software allows Steelcase staff to quickly create reports that visualize energy usage. Courtesy: Rockwell Automation

The Rockwell Automation Global Solutions team surveyed the existing infrastructure and mapped out a specific roadmap for implementing the PlantPAx system prior to design and installation. “The Rockwell Automation team came to our project having executed dozens of similar, successful engagements,” said Boss. “They gave us a lot of advice on how to accommodate fuel source fluctuations so our boilers could operate at top efficiency regardless of what type of coal we were using.” 

The PlantPAx system also was able to utilize existing Allen-Bradley 1771 Remote I/O modules on ancillary equipment controllers, communicating with a central Allen-Bradley ControlLogix controller via an EtherNet/IP network. A standard PC in the control room runs FactoryTalk View Site Edition human-machine interface software to provide operators with comprehensive insight into boiler operations. “Most of our plant processes run on Allen-Bradley controls, so plantwide integration and optimization was much easier using the PlantPAx system,” said Boss. 

After looking at options for improving the efficiency of its boilers, Steelcase then looked to get better insight and control of the energy consumption in its facilities. Having worked closely for more than 25 years with Kendall Electric, a Rockwell Automation PartnerNetwork member and authorized Allen-Bradley distributor, Steelcase was quite familiar with Rockwell Automation products. The company saw value in working with Rockwell Automation to improve its enterprisewide energy monitoring. Ultimately, the Steelcase team selected Rockwell Software RSEnergyMetrix software, favoring the standard off-the-shelf reporting features it included. 

Steelcase worked with the Rockwell Automation Global Solutions team to implement about 100 points of Allen-Bradley PowerMonitor electric metering devices throughout the company’s Grand Rapids and Mexico facilities. Some of the site metering points also gather gas, steam, and air consumption data to be sent directly to ControlLogix and Allen-Bradley MicroLogix controllers, which act as energy data concentrators. From there, energy data is communicated via an EtherNet/IP network to the RSEnergyMetrix software database that is hosted on Steelcase’s virtual server. “Implementing this type of a solution on a virtual server was a fairly new concept,” explained Bolinger. “The Rockwell Automation team worked tirelessly to get the new system running, and they taught us a lot about the system along the way so we could get the most out of our investment.” 

Results

The control system upgrade and energy monitoring projects implemented at Steelcase helped the company achieve its aggressive efficiency and sustainability goals, and provided significant cost savings across the organization. 

Because of its open platform, the Steelcase team can maintain the new control system almost entirely on its own. Also, management can access and troubleshoot the system remotely, which significantly reduces unplanned downtime. For Steelcase, the benefits are visible down to the bottom line. “Because we could add PlantPAx system support to our existing TechConnect contract and eliminate the service agreement with our old DCS vendor, we’re saving around $25,000 per year,” said Newsome, the senior automation engineer. “And, if there’s something we’re unsure of, we can utilize the Rockwell Automation TechConnect team or Knowledgebase online database for timely and cost-effective support that ultimately gives us peace of mind.”

With the new energy management solution, Steelcase can document and quickly address energy events such as voltage sags, surges, or outages. By doing so, the team can reduce downtime and help protect critical production assets from potentially harmful operating situations. Energy management software provides the Steelcase team with visibility into its energy consumption—a critical component for ISO-14001 compliance.

“We can see when something is running hot and consuming more energy than it should, which is an indicator that something needs fixing on the equipment,” explained Newsome. “The Rockwell Automation solution helps us validate maintenance projects and proactively address potential issues before they occur.” 

Prior to the new energy management system, the Steelcase team needed to “guesstimate” the losses resulting from air leaks. Now, management can identify the exact air loss amounts, which ultimately help justify the cost of the system. With improved insight into energy consumption, the Steelcase team can more easily justify investments in newer, more energy-efficient technology. 

Steelcase was one of the first to use the wireless Allen-Bradley PowerMonitor W250 power meter to gather consumption information on individual production lines. Ultimately, the team hopes to capture exactly how much energy it takes to produce a specific product, so the company can include energy costs on its bill of materials. 

“Rockwell Automation engineers truly took a team-centered approach with us, sharing their expertise and helping us take ownership of our own systems,” said Newsome. “Our relationship with Rockwell Automation makes us feel very confident in our abilities to support and optimize the technology we have installed, now and in the future.”

The results mentioned above are specific to Steelcase’s use of Rockwell Automation products and services in conjunction with other products. Specific results may vary for other customers.

Trademark information:                 

 

1771 Remote I/O, Allen-Bradley, ControlLogix, FactoryTalk, MicroLogix, PartnerNetwork, PlantPAx, PowerMonitor, Rockwell Software, RSEnergyMetrix, TechConnect are trademarks of Rockwell Automation Inc.

EtherNet/IP is a trademark of ODVA. 

This article appeared in the February 2013 Industrial Energy Management special section to Control Engineering, CFE Media.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me