Wisconsin hospital uses energy-efficient boiler

St. Elizabeth Hospital in Appleton, Wis., earns the Energy Star designation from the U.S. Environmental Protection Agency as part of a green healthcare initiative.

07/12/2011


St. Elizabeth Hospital, part of Affinity Health System, in Appleton, WISt. Elizabeth Hospital, part of Affinity Health System, in Appleton, Wis., is one of the few hospitals in the U.S. to achieve an energy performance rating in the top 25%  of facilities nationwide, earning them the prestigious Energy Star designation from the U.S. Environmental Protection Agency (EPA). Working closely with Affiliated Engineers, Boldt Construction, and Tweet/Garot Mechanical to design and install the energy-efficient Central Utility Plant, St. Elizabeth’s selected the Hurst Boiler Scotch Marine Series 500 system to help them meet their green healthcare initiative goals.

The 500 Series Hurst Boiler 700 HP system delivers on every front. Ron Piotrowski, Plant Operations for St. Elizabeth Hospital stated the “greatest benefit to the hospital is that the boilers run efficiently with very low excess air and our steam pressure doesn’t deviate from the 60 PSI set-point.” The hospital’s old boiler system used to cycle constantly, even in warm weather. “Now, with outside air temperatures nearing 100 F,” said Piotrowski, “our 700 HP Hurst Boilers don’t even cycle. The high turndown Riello burners on our Hurst boilers allow the system to run efficiently down to 10% of full firing rate.” Sturdivant added that the efficient turndown of the primary 700 HP Hurst boilers will negate the need to purchase and install a separate smaller summer boiler, saving the hospital even more money over the long run.

Hurst Boiler 700 HP Scotch Marine Series 500 boilerLocal Hurst Boiler representative McCotter Energy Systems provided Tweet/Garot Mechanical with design assistance, implementation, and commissioning for the St. Elizabeth Hospital green energy project. President Dan McCotter was pleased to have the opportunity to provide the company’s Hurst Boiler 500 Series ‘high efficiency Red Boiler Package,’ which offers the ‘smart energy’ benefits of the Riello high efficiency burner and integrated touch screen controls with real-time efficiency monitoring.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
January/February 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me