Wireless UPS Paralleling

Powerware, Raleigh, N.C., offers Powerware Hot Sync, a patented paralleling technology that is said to eliminate system-level single-point-of-failure, enabling UPS modules to work in parallel and complete synchronization, for both redundant and capacity systems. The system features two identical modules arranged in a parallel redundant configuration and a parallel tie cabinet connecting the mod...

06/01/2002


Powerware , Raleigh, N.C., offers Powerware Hot Sync, a patented paralleling technology that is said to eliminate system-level single-point-of-failure, enabling UPS modules to work in parallel and complete synchronization, for both redundant and capacity systems. The system features two identical modules arranged in a parallel redundant configuration and a parallel tie cabinet connecting the modules to the critical bus. A common bypass input source allows the modules to synchronize their outputs, even when one or both of the parallel cabinet MOBs are open for maintenance.

The significance of this technology is that it overcomes the primary conundrum that has faced power technology engineers: how to parallel UPS modules to provide N+1, N+2 or higher redundancy without introducing a single-point-of-failure. By eliminating the communication wires between the UPS modules, and employing an algorithm by which each UPS constantly checks its own output for any variation on the critical bus, each UPS operates independently, but in complete synchronization with the other UPS in the system. The result of this operation is that the UPS modules automatically share the critical load, and can selectively trip and remove themselves from the critical bus if inverter failure or some other critical event occurs.

From Pure Power, Summer 2002.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me