Wireless corrosion and sand monitoring system

Emerson Process Management's Roxar CorrLog + Sandlog wireless transmitters are designed to integrate downstream and upstream assets.

09/30/2011


Emerson Process Management's Roxar CorrLog + SandLog Wireless transmitters combine Emerson’s Smart Wireless technology with Roxar corrosion and sand monitoring instrumentation to provide a wireless integrity management solution for protecting operators’ downstream and upstream assets.

At a time when operators are facing continued production challenges from sand and corrosion and all too often a lack of integration across their asset integrity management systems, the new transmitters are designed to provide accurate online monitoring of sand and corrosion, extending equipment life and increasing production from reservoirs.

“We all know how important it is for operators to protect the integrity and extend the life of their downstream and upstream assets, and we also know that the age-old threats of sand and corrosion remain significant obstacles to the successful flow of hydrocarbons from refinery to reservoir,” said Kjell Wold of Emerson Process Management.

Key benefits of the Roxar CorrLog + SandLog Wireless transmitters include:

  • Flexible and cost effective. The wireless transmitters will result in a significant reduction in installation costs compared to wired online systems and will also allow for monitoring in previously inaccessible areas. Furthermore, a 20 meter probe cable between probes and transmitters ensures increased flexibility, optimum positioning and easy maintenance.
  • Increased accuracy and reliability with a low risk of signal loss in high risk applications, better data and trending, and highly sensitive sensors generating improved information for asset integrity protection. All probe functions (Electrical Resistance (ER), Linear Polarization Resistance (LPR) and Galvanic) are integrated within the transmitter and multi-element sand/erosion probes are incorporated within the Roxar SandLog transmitter to provide increased accuracy.
  • Seamless integration. The Roxar CorrLog + SandLog Wireless transmitters are one element of a complete asset integrity system with direct integration through the Smart Wireless Gateway and access to Roxar Fieldwatch, Emerson’s windows-based field monitoring system for advanced data analysis. Probes can be read from other manufacturers and the direct transmission of metal loss values, for example, can be fed into Fieldwatch for improved monitoring and analysis.

The CorrLog and SandLog Wireless Transmitter systems are based on intrusive sensors that are installed into pipes or vessels through an access fittings system. Access systems are divided into low pressure systems, such as retractable probes often used in refineries or chemical plants, and high pressure subsea systems, where the Roxar ROV Retrieval System is recommended. The Roxar CorrLog + SandLog wireless transmitters are certified by ATEX and other standards bodies.

The operating principles of the sand probe are based on the Electrical Resistance (ER) corrosion probe technique which relies on the erosive effects of sand particles on thin non-corrosive elements mounted on a probe inserted into the pipe. The Roxar CorrLog Wireless corrosion transmitter is based on the CorrLog instrument.

www.emersonprocess.com 

Emerson Process Management

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me