Wind Energy Interconnection Standards are Taking Concrete Shape

02/28/2006


The variability of wind-turbine output can raise problems for the interconnections between wind farms and electricity grids, and standards have been lacking to address these designs. However, the Federal Energy Regulatory Commission (FERC) issued a ruling in December establishing new interconnection standards for large generators with capacities of 20 MW and above. And new equipment now being tested could help address special considerations that exist when wind resources constitute an especially high proportion of a grid’s overall load.

The new FERC standard—Order No. 661-A—is based on proposals developed in negotiations between the American Wind Energy Assn. and the North American Electric Reliability Council. Specifically, the document covers low-voltage ride-through requirements and power-factor issues along with providing a transition period for currently installed turbines.

Smaller grids often face particular difficulty incorporating wind power’s fluctuating resources into their operations. In general, wind-power contributions cannot total more than 10% to 20% of a grid’s overall generating capacity, according to Karl Stahlkopf, Hawaiian Electric Co. Inc.’s (HECO), chief technology officer. However a new device invented by Stahlkopf and now being tested in HECO’s system helps even out fluctuations by storing energy from gusts before related spikes hit the grid. Stahlkopf says his invention can increase wind-power’s contribution to 50% of connected capacity, which could be a big advantage for remote grids, like those on Hawaii’s islands.

Developers continue to plan new wind-farm installations as standards and technologies mature. Texas is planning to add to its already large wind-turbine inventory with a new wind farm planned for completion this year in ShackelfordCounty, in the north-central area of the state. The project’s initial phase will total 200 MW. Two additional 200 MW phases are being considered for the site.

In other wind power news, a Wind Power Symposium focusing on technology, economics and politics of wind power is scheduled for April 20-21, in WashingtonD.C. Four organizations, including the Institute of Electrical and Electronics Engineers (IEEE), the North American Electric Reliability Council (NERC), the American Wind Energy Association (AWEA) and the Utility Wind Integration Group (UWIG), have announced plans to co-sponsor and cooperate in this major symposium on the current status of wind power and electric utilities. For more information, click here .





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me