Why should plumbing designers embrace Revit?

Revit functions differently from AutoCAD and has some unique benefits for plumbing engineers as a result.

08/21/2013


Some of the benefits Autodesk Revit offers include:

  • Creates an opportunity for the designer to better understand the design.
  • Delivers a single model with dynamic views you can customize to show specific components, such as a lighting plan, ceiling to slab view, large mechanical spaces, central plants, and ceiling plenums. Sections can be cut and displayed quickly for any area as a result of the comprehensive information available in the model.
  • Allows designers the ability to make a change in one place and have that change automatically and immediately replicated in every place it should occur throughout the model.
  • Offers the capability to pull data like fixture units and flow for sizing.
  • Provides the ability to set up typical design and document schedules that can rapidly increase documentation time.
  • Gives designers the functionality to create Groups of typical connections that can be designed and copied to other floors, as well as to reuse data-rich plumbing Families that can cut future Families development time.
  • Delivers a higher level of model detail when using manufacturer-specific fittings and accessories.
  • Offers systems data that provides in-depth detail of pipe length and fitting sizes for crucial mechanical equipment selections for hospitals and labs.
  • Supports working in a collaborative model that forces interdisciplinary coordination, which ultimately produces a better product for the owner.

Juncheng (James) Yang is a Senior Associate and Plumbing Section Head at GHT Limited. He has more than 15 years of experience delivering highly creative, technically exceptional plumbing designs for commercial, governmental, and institutional projects



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me