Webcast: Variable frequency drives (VFDs), variable speed drives (VSDs), and motors

Engineers must understand how the components in the systems they design use power and how they can be optimized without compromising traditional design values. Standard induction motors use (and waste) electricity.

06/11/2015


Engineers must understand how the components in the systems they design use power and how they can be optimized without compromising traditional design values. Standard induction motors use (and waste) electricity. Total motor energy usage for the industrial sector outstrips commercial usage by roughly 3:1. To reduce operational costs across all nonresidential buildings, variable frequency drives (VFDs) and variable speed drives (VSDs) are frequently used with ac induction motors that operate pumps, fans, compressors, or similar equipment with variable load profiles.

Although engineers have little control over the applicable efficiency standards and codes they are mandated to follow, they are still tasked with designing appropriately sized and functional systems. The adoption of more stringent energy codes and standards has put greater emphasis on energy efficiency in engineering designs. Efficiency requirements will only become more stringent. This webcast addresses the efficiency standards that apply to ac induction motors and the systems in which they operate, load issues, applications, and harmonic mitigation.

Learning objectives:

  • The audience will understand the requirements of the applicable codes and standards, including ASHRAE Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings; International Energy Conservation Code (IECC); Energy Policy and Conservation Act of 1975 (EPCA-1975); Energy Policy Act of 1992 (EPAct-1992); Energy Independence and Security Act of 2007 (EISA-2007); and NEMA MG 1-2011 motor standard for manufacturers.
  • Attendees will learn how load affects the speed range, size, and efficiency of ac induction motors.
  • Attendees will know when to specify closed-loop versus open-loop drives for various applications.
  • Viewers will learn how to minimize harmonics typically associated with VFDs.

Moderator:

Jack Smith, Consulting-Specifying Engineer, and CFE Media LLC

Presenters:

  • John Yoon, PE, LEED AP, senior staff electrical engineer, McGuire Engineers Inc., Chicago
  • Kenneth L. Lovorn, PE, president, Lovorn Engineering Associates, Pittsburgh


Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me