Webcast: Variable frequency drives (VFDs), variable speed drives (VSDs), and motors

Engineers must understand how the components in the systems they design use power and how they can be optimized without compromising traditional design values. Standard induction motors use (and waste) electricity.

06/11/2015


Engineers must understand how the components in the systems they design use power and how they can be optimized without compromising traditional design values. Standard induction motors use (and waste) electricity. Total motor energy usage for the industrial sector outstrips commercial usage by roughly 3:1. To reduce operational costs across all nonresidential buildings, variable frequency drives (VFDs) and variable speed drives (VSDs) are frequently used with ac induction motors that operate pumps, fans, compressors, or similar equipment with variable load profiles.

Although engineers have little control over the applicable efficiency standards and codes they are mandated to follow, they are still tasked with designing appropriately sized and functional systems. The adoption of more stringent energy codes and standards has put greater emphasis on energy efficiency in engineering designs. Efficiency requirements will only become more stringent. This webcast addresses the efficiency standards that apply to ac induction motors and the systems in which they operate, load issues, applications, and harmonic mitigation.

Learning objectives:

  • The audience will understand the requirements of the applicable codes and standards, including ASHRAE Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings; International Energy Conservation Code (IECC); Energy Policy and Conservation Act of 1975 (EPCA-1975); Energy Policy Act of 1992 (EPAct-1992); Energy Independence and Security Act of 2007 (EISA-2007); and NEMA MG 1-2011 motor standard for manufacturers.
  • Attendees will learn how load affects the speed range, size, and efficiency of ac induction motors.
  • Attendees will know when to specify closed-loop versus open-loop drives for various applications.
  • Viewers will learn how to minimize harmonics typically associated with VFDs.

Moderator:

Jack Smith, Consulting-Specifying Engineer, and CFE Media LLC

Presenters:

  • John Yoon, PE, LEED AP, senior staff electrical engineer, McGuire Engineers Inc., Chicago
  • Kenneth L. Lovorn, PE, president, Lovorn Engineering Associates, Pittsburgh


Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me