Vision sensor for pick-and-place applications

The FQ-M vision sensor by Omron comes with Ethernet and EtherCAT embedded for easy integration and an incremental encoder for tracking and calibration.

03/08/2012


The FQ-M vision sensor by Omron comes with Ethernet and EtherCAT embedded for easy integration and an incremental encoder for tracking and calibration. Courtesy: OmronOmron introduced a vision sensor developed specifically to meet the needs of pick-and-place applications. Highly compact, and with a processing speed of 5,000 pieces per minute even with full 360 degree rotation, the FQ-M vision sensor comes with Ethernet and EtherCAT embedded for ease of integration into any environment, and includes an incremental encoder for easy tracking and calibration. The FQ-M is configured for guidance of dynamic pick-and-place robots using Omron’s Sysmac Studio software, and is complemented by the palm-sized TouchFinder console for local monitoring and access to functions and settings.

The FQ-M is a smart camera that meets all the needs of demanding object recognition and tracking applications, combining a camera, image processing functionality and flexible communications options into a single compact package. 

The FQ-M vision sensor tightly integrates core automation components with a common network and a single programming and configuration interface. It communicates with other devices either via EtherCAT or via standard Ethernet, or a combination of the two. 

Object detection is based on a newly developed contour-based search algorithm which ensures the highest reliability, regardless of changing lighting conditions, reflection and object inclination. The algorithm can even cope with overlapped or partially hidden objects. With this high performance algorithm and the high speed image processing capability, the FQ-M can detect up to 32 pieces at once with absolute stability, and 5,000 pieces per minute. The incremental encoder interface simplifies initial calibration of the system, and enables on-the-fly tracking for tightly synchronized control. The FQ-M is able to output position coordinates and the corresponding encoder values, and is able to manage the object queue so that no object’s coordinates are duplicated.

Set-up of the FQ-M vision sensor is performed through the Vision Editor of the Sysmac Studio software, which provides intuitive, icon-driven configuration that makes it easy to achieve the optimum vision setting. The Vision Editor also provides comprehensive trending and logging functions. For easy integration into robot pick-and-place systems, the communication wizard makes it easy to configure any robot protocol either as a server or as a client without complex programming.

For ease of monitoring and for access to parameters and settings, the TouchFinder console provides a 3.5-in. TFT color touch screen. Users can view images in real time, zoom in, zoom out and freeze images for closer manual inspection. The TouchFinder can also show a variety of measurements, including the last result, the last no-go result, a trend monitor and histograms. It can also log the data from measurement results and measured images. Users navigate through the various functions via the intuitive touch screen interface.

Measuring just 110 x 75 x 50 mm, the FQ-M vision sensor is compact enough to make mounting simple in even the most challenging automation environments. For ultimate flexibility, the FQ-M provides a standard C-Mount lens attachment, enabling users to select from a wide range of compatible lenses for optimized system performance.

Omron Industrial Automation

www.omron247.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

Read more about machine vision at controleng.com/machinevision and see more on industrial sensors at controleng.com/sensors.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me