Vision and motion hardware added to controller platform

A reconfigurable Camera Link frame grabber for embedded vision and a motion module were added to the CompactRIO controller platform from National Instruments.

12/13/2011


National Instruments (Nasdaq: NATI) introduced two new additions to its NI reconfigurable I/O (RIO) technology including a reconfigurable Camera Link frame grabber for demanding embedded vision applications and a motion module for the NI CompactRIO platform.

National Instruments added a frame grabber and a motion module were added to their CompactRIO platform to allow for greater flexibility and versatility for engineering operations. Courtesy: NIThe NI PCIe-1473R frame grabber is a PC-based embedded vision board that combines field-programmable gate array (FPGA) technology with a Camera Link interface to help engineers create high-performance embedded imaging and inspection applications. The NI 9502 brushless servo drive C Series module makes it possible for engineers to drive brushless servo motors, including six new custom NI motor options, directly from the reconfigurable CompactRIO system to address advanced motion control challenges.

The NI PCIe-1473R frame grabber is ideal for advanced inspection and imaging applications that require image preprocessing and high-speed control such as medical imaging, web and surface inspection and high-speed sorting. Engineers and scientists can program the new frame grabber’s onboard FPGA with the NI LabVIEW FPGA Module for custom image processing and analysis in real time, with little to no CPU intervention. The frame grabber combines the onboard FPGA with a high-bandwidth 850 MB/s Camera Link bus, which supports a range of Camera Link configurations up to 10 taps and 80 bits. The NI PCIe-1473R also supports Power over Camera Link (PoCL) to directly power cameras with no additional cables or external power supply. With such features, the frame grabber is an off-the-shelf solution that makes it possible for engineers to create high-performance imaging applications without spending substantial time and money to develop a custom design.

With the addition of the NI 9502 motion drive module for CompactRIO, engineers can now power brushless, stepper or brushed servo motors directly with NI C Series modules to provide a compact solution for integrating motion into advanced control, monitoring and test systems. The NI 9502 offers 4 A continuous/8 A peak current and multiple commutation modes. To complement the module, NI is also releasing six three-phase brushless motors that are specifically designed for maximum performance and direct connectivity with the NI 9502. With these features and more, the NI 9502 helps engineers implement proprietary custom drive control algorithms at the FPGA level through LabVIEW FPGA, eliminating the need for custom firmware from a drive manufacturer.

NI RIO technology combines LabVIEW system design software with commercial off-the-shelf hardware to simplify development and shorten time to market when designing advanced control, monitoring and test systems. NI RIO hardware, which includes CompactRIO, NI Single-Board RIO, R Series boards and the PXI-based NI FlexRIO, features an architecture with powerful floating-point processors, reconfigurable FPGAs and modular I/O. All NI RIO hardware components are programmed with LabVIEW to give engineers the ability to rapidly create custom timing, signal processing and control for I/O without requiring expertise in low-level hardware description languages or board-level design.

www.ni.com 

National Instruments

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me