VFD protection relay

The EL731 ac/dc Sensitive Earth-Leakage Relay by Littelfuse can detect ground currents.

06/01/2012


Littelfuse Inc.’s EL731 ac/dc Sensitive Earth-Leakage Relay can detect ground currents—even in resistance-grounded electrical systems—all the way down to 0 Hz. This makes it ideal for protecting variable-frequency drives (VFDs) that may operate at low speeds, during which ac current approaches dc. The EL731 relay provides complete range of ground-fault protection in VFDs from 0 to 15,000 Hz in one device, saving cost and panel space compared to other relays. The EL731 uses a patented approach that enables the relay to detect the location of ground faults and makes it equally useful for ac, mixed ac/dc, and dc systems, including low-voltage 6-pulse VFDs commonly used on motors up to 250 hp. The relay is ideal for protecting VFDs operating in resistance-grounded electrical systems, which are growing in popularity because of their ability to reduce arc-flash hazards. The on-board ground-fault protection that comes with VFDs is generally not sensitive enough to detect a ground fault in resistance-grounded systems.

Littelfuse Inc.

www.littelfuse.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me