VFD for HVAC systems

The P-Series line of variable frequency drives is available from Cerus Industrial.

06/28/2012


The P-Series line of variable frequency drives by Cerus Industrial. Courtesy: Cerus IndustrialCerus Industrial enhanced its P-Series line of variable frequency drives (VFDs) for HVAC use with control options and safety features, and an application-based commissioning tool called FastApp, designed to save time when setting up a wide range of HVAC applications. With FastApp, HVAC motor control parameters are now easier to set up via the keypad on the drive enclosure, and include a multitude of display and control options. With this wider array of options, users around the world with different HVAC applications can set up their control systems. The enhanced VFDs also have safety features to protect motors from damage due to conditions such as belt loss. If the under level detection feature is selected and the motor runs at a speed above a set amount for longer than a set amount of time and with the load current at less than a set level, the VFD will trip.

Cerus Industrial Inc.

www.cerusind.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me