Vertical stack unit

The Tranquility Vertical Stack (TSL) Series ducted heat pump unit provides independent metering capabilities and features loss-of-charge and high-pressure switches.

08/18/2014


The Tranquility Vertical Stack (TSL) Series ducted heat pump unit provides independent metering capabilities and features loss-of-charge and high-pressure switches and a lockout safety circuit reset function. Courtesy: ClimateMasterClimateMaster's Tranquility Vertical Stack (TSL) Series ducted heat pump unit provides independent metering capabilities for a wide scope of building applications, including office, education, hospitality, and multi-family projects. The ClimateMaster TSL Series unit is available in ¾- to 3-ton capacities and features top supply air discharge openings that allow for easy configuration of the unit in ducted applications. The TSL Series unit also features loss-of-charge and high-pressure switches, a lockout safety circuit reset function at the thermostat or disconnect, a LED fault indicator, 24 Vac or dry contact alarm options, and a low-temperature cutout on the water coil. 

ClimateMaster Inc.

www.climatemaster.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me