Variable speed wet rotor circulators

Grundfos Pumps produces a permanent magnet, variable speed wet rotor circulator, reduces power consumption.

02/08/2011


Grundfos MAGNA variable speed wet rotor circulatorThe MAGNA, from Grundfos, with its permanent magnet motor design allegedly reduces power consumption by 50% or more. The unique patented AUTOADAPT feature controls pump performance automatically within defined performance range, reportedly ensuring lowest possible energy consumption without sacrificing comfort. It’s purportedly easy to install and simple to operate for replacement applications.

Standard Features include:

  • Permanent magnet motor design that will avoid motor slippage problems common to induction-type motors, while delivering a starting torque four times higher than a standard induction motor.
  • AUTOAdapt function automatically modulates circulator performance to match ever-changing system demand, cutting power consumption by a minimum of 50%, as compared with other circulators in its class.
  • Plug-and-play convenience: Ten-foot-long line cord connects the circulator to a wall outlet, with no wiring required, eliminating the need to open a terminal box to make electrical connections
  • Integrated frequency converter allows built-in intelligence analyzes current conditions and adjusts performance accordingly to ensure maximum efficiency during operation
  • Low Noise Level: When in operation the noise level of the MAGNA is less than 35 db, equivalent to a whispered voice.

Grundfos



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me