Variable air volume system

The VariCool EZ-Fit is a self-contained variable air volume (VAV) system that comes in a single-module system that provides up to 35 tons of cooling and a dual module system that provides up to 70 tons.

02/16/2015


The VariCool EZ-Fit is a self-contained variable air volume (VAV) system that comes in a single-module system that provides up to 35 tons of cooling and a dual module system that provides up to 70 tons. Courtesy: United CoolAirThe VariCool EZ-Fit from United CoolAir is a self-contained variable air volume (VAV) system. It comes in a single-module system that provides up to 35 tons of cooling and a dual module system that provides up to 70 tons. The modules can be ganged together or used separately. The resealable refrigerant fittings allow the unit to be shipped split without losing the refrigerant charge. They are designed to fit through standard doorways, in elevators, and down hallways, which make them useful for retrofit and renovation projects. Other features include a hot gas bypass, backward inclined blades, factory-mounted variable frequency drive (VFD) controllers, and interlaced evaporator coils.

United CoolAir

www.unitedcoolair.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me