Upgrades to circuit breaker combination starters

Schneider Electric has upgraded its range of Square D Circuit Breaker Combination Starters to include energy efficient, longer lasting LED pilot lights, enhanced door seals, and PowerPact eMCP circuit breakers.

11/24/2010


Schneider Electric has announced major upgrades to its range of its Square D Circuit Breaker Combination Starters. Square D, the reported original inventor of combination starters in the early 1930s, is now offering NEMA Combination Starters that include energy efficient, longer lasting LED pilot lights, enhanced door seals and the most noteworthy upgrade—PowerPact eMCP circuit breakers, which improves product flexibility and safety by providing higher short-circuit current protection.

The new combination starters fit numerous commercial building applications including office buildings, construction and industrial markets. Key features and benefits of the upgraded combination starters include:

  • PowerPact eMCP circuit breakers: Features built-in quality that protects higher amp flow and offers greater in-field flexibility. Includes longer-lasting, energy efficient 30 mm LED pilot lights, and specially designed, pliable “foam-in-place” cabinet seals that protect from harmful outside elements providing a secure seal each time it’s closed. 
  • Flexible Fit: Accommodates standard 9070TF control power transformers allowing for a wide range of fits and easier modifications. NEMA size 0-5 Combination Starters use only 5 eMCP frames to meet many applications.
  • Easy Access and Protection: Streamlined installation, wiring, maintenance and field modifications with convenient door-mounted pilot devices. eMCP dials can be set to comply with NEC 430.52 allowing users to handle transient inrushes without tripping.
  • Redesigned Operating Mechanism and Disconnect Switch: Enables facility managers to operate smarter with the capability to reset the overload without special tools. Also, the sturdy construction of the non-removable door helps ensure a safer, more secure starter.

For more information on the Square D by Schneider Electric Combination Starters, visit www.schneider-electric.us/go/ComboStarters

Schneider Electric

www.schneider-electric.us


- Edited by Amanda McLeman, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me