Turning up the data center heat

Temperatures may be going up in data centers if the advice of one expert is taken.

06/16/2009


Temperature may play less of an impact in the design of data

centers if the advice of power and cooling expert Jim Simonelli is taken into

account, states an article in PC World.

According to Simonelli, keeping a data center at 68 F is no

longer a necessity thanks to new technology that allows storage and networking

equipment to run properly at temperatures exceeding 100 F. The idea is

consistent to a report published in 2007 by Google that stated that hot conditions do not have an affect on disk drives and

servers.

The new thinking may give companies the chance to slash their energy budget

by allowing the rooms to operate at 80 F or above as opposed to the previously

preferred 68 F. Over-heating no longer is a risk thanks to updated technology

such as server virtualization, which leads to fewer machines doing the same

amount of work as several previously did.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me