Trip Unit

All the electrical industry buzzwords—system coordination, selectivity, reliability, arc flash protection—are addressed with GE’s trip unit.

09/14/2010


Now offered in GE Spectra SG600 and SK1200 circuit breakers, and backwards compatible with existing Spectra MicroVersa Trip breakers, GE’s microEntelliGuard trip unit delivers: 

  • Flexible time-current curve shaping in the industry for system coordination
  • Instantaneous ZSI (Zone Selective Interlocking) for selectivity
  • Waveform capture and event log for reliability
  • Reduced energy let-through (RELT) for arc flash protection.

The trip unit also features:

  • An HMI (human machine interface) based on the same platform as the trip units that provides a backlit LCD display with five-button tactile keypad and LED status to show the “health” of trip unit
  • Fully adjustable time-current curves with multiple curve shapes, slopes, and delay bands
  • Ground Fault Trip or Alarm with multiple slopes for system coordination
  • Current metering is a standard feature, with options for power, energy and reactive power metering and waveform capture
  • Event Log with date/time stamp to record the last 10 events
  • Test set jack for GTUTK20 test kit
  • Modbus communications system with user-selectable address assignment for communication directly with building-power management systems.

Specification engineers are available to assist end-users and consulting engineers with system design to fully optimize the capabilities of the microEntelliGuard trip unit.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me