Transfer switch-based power systems

Series 300 Generator Paralleling System is pre-packaged transfer switch-based power systems for paralleling generators.

05/11/2016


Series 300 Generator Paralleling System is pre-packaged transfer switch-based power systems for paralleling generators. Courtesy: ASCOASCO's Series 300 Generator Paralleling System is pre-packaged transfer switch-based power systems for paralleling generators. It is capable of paralleling 2 to 4 genset installations and managing 4 to 8 transfer switch load blocks at distributed data centers, commercial and telecom operations, oil and gas processes, and health care, government, agricultural, and educational facilities. The system is UL 891 listed and distributes power by load prioritization and to control load bus optimization, generator load demand, and generator power metering. The operator touch screen includes metering, event and alarm logs, bus optimization and load demand set up, and manual paralleling. The Series 300 incorporates closed transition transfer switch mechanism and is available from 208 to 600 V.

ASCO

www.ascoapu.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me